GPM40-12 SL Power ( Ault / Condor ), GPM40-12 Datasheet - Page 2

no-image

GPM40-12

Manufacturer Part Number
GPM40-12
Description
Power Supply, Single Output; 40 W; Single Output; 12 V; 3.3 A (Max.); 20 ms;
Manufacturer
SL Power ( Ault / Condor )
Type
Medicalr
Datasheet

Specifications of GPM40-12

Brand/series
GPM40 Series
Configuration
Open-Frame
Current, Input
1.3 A (Max.) @ 120 VAC, 60 Hz
Current, Leakage
25 uA (Normal), 35 uA (Single Fault) @ 120 VAC @ 60 Hz Input⁄40 uA (Normal), 60 uA (Single Fault) @ 264 VAc @ 60 Hz Input
Current, Output
3.3 A (Max.)
Dimensions
5 in. L x 3 in. W x 1.28 in. H
Hold Time
20 ms
Mounting Type
Panel
Noise, Output
0.5 % rms
Number Of Outputs
1
Operation
Switching
Output
12 VDC @ 3.3 A
Output Type
Single Output
Overvoltage Protection
124 % ±12 %
Power Rating
40 W
Power, Output
40 W
Primary Type
AC-DC
Special Features
Remote Sense
Standards
Approved to UL2601-1, EN60601-1 and CSA22.2 No. 601, CE Marked to LVD
Voltage, Input
85 to 264 VAC
Voltage, Output
12 VDC
Note: For 48 volt model, GPC40-48 or GPM40-48, contact factory for availability.
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. To maintain these regulation conditions, the 5.1V current must be at least 1/4 of V2 and not greater than 5 times the V2 current.
C. Requires +5.1V to be adjusted within ±1% with at least a 0.4A load to maintain regulation on this output.
D. Add “G” suffix to model number for RoHS compliant model.
Commercial
Model
GPC40A
GPC40B
GPC40D
GPC40-3.3
GPC40-5
GPC40-9
GPC40-12
GPC40-15
GPC40-24
GPC40-28
ENVIRONMENTAL SPECIFICA-
TIONS
Temperature (A)
Humidity (A)
Shock (B)
Altitude
Vibration (C)
GPC40/GPM40 MECHANICAL SPECIFICATIONS
3
Medical
Model
GPM40A
GPM40B
GPM40D
GPM40-3.3
GPM40-5
GPM40-9
GPM40-12
GPM40-15
GPM40-24
GPM40-28
OPERATING
See individual specs.
0 to 95% RH
20 g
-500 to 10,000 ft
1.5 g
Output No.
pk
rms’
1
2
3
1
2
3
1
2
3
1
1
1
1
1
1
1
0.003 g
2
/Hz
Output
+5.1 V
+5.1 V
+5.1 V
+12 V
+15 V
+24 V
-12 V
-15 V
-12 V
3.3 V
12 V
15 V
24 V
28 V
5 V
9 V
NON-OPERATING
-40 to +85°C
0 to 95% RH
40 g
-500 to 40,000 ft
5 g
rms’
pk
0.026 g
2
/Hz
Minimum
Output
0.4 A
0.4 A
0.4 A
0 A
0 A
0 A
0 A
0.A
0.A
0 A
0 A
0 A
0 A
0 A
0
0
A. Units should be allowed to warm up/operate under non-condensing
B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction,
C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to
onditions before application of power.
3 orthogonal axes, total 6 shocks.
2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and
1 hr./axis non-operating.
Maximum
3
Output
0.4 A
0.4 A
0.4 A
4.5 A
3.3 A
2.7 A
1.7 A
1.4 A
4 A
2 A
4 A
2 A
4 A
1 A
8 A
8 A
Output
Peak
0.7 A
0.7 A
1.5 A
0.7 A
4.2 A
3.3 A
2.1 A
1.8 A
10 A
10 A
5 A
3 A
5 A
3 A
5 A
6 A
Noise P-P
120 mV
120 mV
150 mV
150 mV
240 mV
120 mV
120 mV
150 mV
240 mV
280 mV
50 mV
50 mV
50 mV
35 mV
50 mV
90mV
Regulation
Total
2%
5%
3%
2%
5%
3%
2%
5%
3%
2%
2%
2%
2%
2%
2%
2%
Notes
B,C
B,C
B,C
C
C
C

Related parts for GPM40-12