PIC18F8520-I/PT Microchip Technology Inc., PIC18F8520-I/PT Datasheet - Page 228

no-image

PIC18F8520-I/PT

Manufacturer Part Number
PIC18F8520-I/PT
Description
80 PIN, 32 KB FLASH, 2048 RAM, 68 I/O
Manufacturer
Microchip Technology Inc.
Datasheet

Specifications of PIC18F8520-I/PT

A/d Inputs
16-Channel, 10-Bit
Comparators
2
Cpu Speed
10 MIPS
Eeprom Memory
1024 Bytes
Input Output
68
Interface
I2C/SPI/UART/USART
Memory Type
Flash
Number Of Bits
8
Package Type
80-pin TQFP
Programmable Memory
32K Bytes
Ram Size
2K Bytes
Speed
40 MHz
Timers
2-8-bit, 3-16-bit
Voltage, Range
2-5.5 V
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F8520-I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18F8520-I/PT
Manufacturer:
MICROCHIP-Pb
Quantity:
6 416
Part Number:
PIC18F8520-I/PT
Manufacturer:
MICROCHIP-Pb
Quantity:
3 827
Part Number:
PIC18F8520-I/PT
Manufacturer:
MICROCHIP-Pb
Quantity:
5 738
Part Number:
PIC18F8520-I/PT
Manufacturer:
MICRCOHI
Quantity:
20 000
PIC18F6520/8520/6620/8620/6720/8720
FIGURE 20-3:
20.6
The comparator interrupt flag is set whenever there is
a change in the output value of either comparator.
Software will need to maintain information about the
status of the output bits, as read from CMCON<7:6>, to
determine the actual change that occurred. The CMIF
bit (PIR registers) is the Comparator Interrupt Flag. The
CMIF bit must be reset by clearing ‘0’. Since it is also
possible to write a ‘1’ to this register, a simulated
interrupt may be initiated.
The CMIE bit (PIE registers) and the PEIE bit (INTCON
register) must be set to enable the interrupt. In addition,
the GIE bit must also be set. If any of these bits are
clear, the interrupt is not enabled, though the CMIF bit
will still be set if an interrupt condition occurs.
DS39609B-page 226
Comparator Interrupts
COMPARATOR OUTPUT BLOCK DIAGRAM
Set
CMIF
bit
To RF1 or
RF2 pin
Bus
Data
Read CMCON
From
Other
Comparator
Q
Q
EN
CL
D
EN
The user, in the Interrupt Service Routine, can clear the
interrupt in the following manner:
a)
b)
A mismatch condition will continue to set flag bit CMIF.
Reading CMCON will end the mismatch condition and
allow flag bit CMIF to be cleared.
D
Note:
Any read or write of CMCON will end the
mismatch condition.
Clear flag bit CMIF.
Reset
Read CMCON
MULTIPLEX
If a change in the CMCON register
(C1OUT or C2OUT) should occur when a
read operation is being executed (start of
the Q2 cycle), then the CMIF (PIR
registers) interrupt flag may not get set.
Port pins
+
-
 2004 Microchip Technology Inc.
CxINV