117632-52 AMETEK, 117632-52 Datasheet

no-image

117632-52

Manufacturer Part Number
117632-52
Description
ByPass Blower, 400 W, 3stg, SF, msc
Manufacturer
AMETEK
Type
Canisterr
Datasheet

Specifications of 117632-52

Air Flow
65 CFM
Brand/series
IntelliGen™
Configuration
Bypass
Controls
Mechanical
Current, Rating
5 A
Diameter, Inlet
1.25 "
Diameter, Outlet
1.25 "
Dimensions
145Dia x 175.01L mm
Power, Rating
400 W
Special Features
Speed Control
Static Pressure
72 in.-H2O
Temperature, Operating, Maximum
+50 °C
Temperature, Operating, Minimum
0 °C
Termination
Terminals
Voltage, Rating
240 VAC
Weight
6 lbs.
Lead Free Status / Rohs Status
RoHS Compliant part
54
5.7” (145mm) BLDC Bypass Blower
400 Watt, 240 Volt Standard Flow
NOTES:
• Nominal Input Voltage: 240 Volts AC RMS ±10%, 50/60Hz.
• Input Current: 5 amps AC RMS maximum.
• Temperature: Working Air: 0°C to 50°C, Ambient Air: 0°C to 50°C, Storage Air: -40°C to 85°C.
• Dielectric Testing: 1500 volts AC RMS 60Hz applied for one second between input pins and ground, 3mA leakage max.
• Speed Control: E (Electrical): Pulse Width Modulation or Analog input voltage (user supplied), 0 to 10 Volts DC nominal, 10mA maximum, 3 to 15 volts DC
• Optional: IntelliGen™ controller available for customized performance.
* These part numbers are available through AMETEK Technical & Industrial Products’ distributors.
Stages
Vacuum, Maximum
(Sealed Vacuum)
Pressure, Maximum
(Sealed Pressure)
Flow Rate, Maximum
(Open Flow)
Inlet/Outlet Diameter
(Dimension “D” above)
Length
(Dimension “I” above)
Length
(Dimension “L” above)
Ø
(32.0)
1.26
INCH
(MM)
MAX.
Blower Data
maximum. Access to sensitivity adjustment for 0 to 10 VDC speed control. (Ref. pin connection).
M (Mechanical): A potentiometer is available for speed control of the blower. The potentiometer can be preset for a specifi c speed. Access to
speed adjustment.
33°
SEE DETAIL
43°±2°
USE THIS HOLE FOR
GROUNDING OR EARTHING.
REFER TO APPROPRIATE
LISTING OR REGULATORY
AGENCY FOR PROPER METHOD
OF GROUNDING OR EARTHING.
(1) Ø
LOCATED AS SHOWN ON
Ø
(162.56)
Ø.024/(.61) A
6.400
.168±.003
(4.27±.07)
(60.45)
2.38
BOLT CIRCLE.
“E”
M
HOLE THRU,
OR
SENSITIVITY
CONTROL
Unit of Measure
“M”
S
37°±2°
C L
in. H
in. H
inches
inches
inches
mBar
mBar
m
CFM
mm
mm
mm
3
/hr
2
2
ACCESS FOR MECHANICALLY
ADJUSTED SPEED CONTROL
O
O
(81.79±1.52)
(15.0)
3.22±.06
.59
“L”
.015/(.38)
117634 M* / 117640 E*
(26.42)
1.04
129.03
31.75
64.26
1.25
2.53
5.08
119
28
69
30
74
70
1
“l”
(1.3)
.05
-A-
INTAKE
MAX BOW
TYP. BOTH
ENDS
(22.35±3.3)
AIR
.88±.13
5
Ø
(149.4)
4
5.88
3
POST HEADER ASSEMBLY
DETAIL
2
(4) Ø
LOCATED AS SHOWN ON A
MAX.
Ø
Standard Flow
117633 M / 117639 E
Part Number
(165.1)
1
6.500
(.4.27±.07)
.168±.003
EXHAUST
“E”
LOW
GROUND
AC INPUT
(VOLTAGE 240±10%)
HIGH
AIR
"D"
Ø.024/.61 A
"D"
BOLT CIRCLE.
152.15
31.75
31.75
}
1.25
1.25
5.99
2
112
126
114
1
45
51
67
ISOLATED SPEED
INPUT REQUIRED
2
HOLES THRU,
CONTROL
0-10. D.C.
M
(95.0)
3.74
47°
43°
5
117632 M* / 117638 E*
4
3
(3X)
POST HEADER ASSEMBLY
90°
DETAIL
2
1
175.01
31.75
54.36
1.25
2.14
6.89
149
174
110
60
72
65
3
“M”
AC INPUT
(VOLTAGE 240±10%)
NOT USED
GROUND
NOT USED

Related parts for 117632-52

117632-52 Summary of contents

Page 1

... LOW CONTROL 0-10. D.C. HIGH INPUT REQUIRED GROUND AC INPUT (VOLTAGE 240±10%) “E” DETAIL DETAIL POST HEADER ASSEMBLY POST HEADER ASSEMBLY Part Number Standard Flow 117633 M / 117639 E 117632 M* / 117638 112 149 51 72 126 174 67 65 114 110 1.25 1.25 31.75 31 ...

Page 2

... AMETEK BLDC motor controllers. Actual performance will vary depending on the operating environment and application. AMETEK products are not designed for and should not be used in medical life support applications. AMETEK reserves the right to revise its products without notifi ...

Related keywords