G308A210 Red Lion Controls, G308A210 Datasheet

no-image

G308A210

Manufacturer Part Number
G308A210
Description
OPERATOR INTERFACE, COLOR TFT LCD, 8.4 INCH, 24V, 32MB FLASH MEMORY
Manufacturer
Red Lion Controls
Type
Color Graphicr
Datasheet

Specifications of G308A210

Brand/series
G3 Series
Communication
Extensive List of Industrial Devices
Dimensions
10.32 × 8.18
Display Size
8 In.
Memory
32 Mb Flash
Mounting Type
Panel
Port Style
RS-232/422/485 and Ethernet
Primary Type
Operator Interface
Resolution
640 × 480
Resolution, Display
640 × 480
Size
8.4" Color TFT
Special Features
Web-Server, UL and Class I Div.2
User Interface
Touchscreen
Voltage, Supply
24 V
Configuration Is Stored In Non-volatile Memory
4 Mbyte Flash for G306M
Lead Free Status / Rohs Status
RoHS Compliant part
For Use With
PLCs, Motor Drives and other Industrial Devices
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
PROCESS CONTROL EQUIPMENT
PROCESS CONTROL EQUIPMENT
GENERAL DESCRIPTION
expected from high-end units with a very affordable price. It is built around a
high performance core with integrated functionality. This core allows the G308
to perform many of the normal features of the Paradigm range of Operator
Interfaces while improving and adding new features.
high-speed RS232/422/485 communications ports and Ethernet 10 Base T/100
Base-TX communications. In addition, the G308 features USB for fast downloads
of configuration files and access to trending and data logging. A CompactFlash
socket is provided so that Flash cards can be used to collect your trending and data
logging information as well as to store larger configuration files.
allows a user to easily view and enter information. Users can enter data through
the touchscreen or front panel 7-button keypad.
SAFETY SUMMARY
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller.
MODEL G308C1/A2 - 8" COLOR TOUCHSCREEN
C C
C
The G308 Operator Interface Terminal combines unique capabilities normally
The G308 is able to communicate with many different types of hardware using
In addition to accessing and controlling of external resources, the G308
All safety related regulations, local codes and instructions that appear in the
Do not use the controller to directly command motors, valves, or other
installation and operation of the unit.
Read complete instructions prior to
CompactFlash is a registered trademark of CompactFlash Association.
U L
R
U L
CAUTION: Risk Of Danger.
R
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF
COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,
DIVISION 2
US LISTED
US LISTED
US LISTED
The protective conductor terminal is bonded to conductive
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.
43NH
3RSD
FOR USE IN HAZARDOUS LOCATIONS:
Class I, Division 2, Groups A, B, C, and D
CAUTION: Risk of electric shock.
1
CONTENTS OF PACKAGE
ORDERING INFORMATION
1
2
3
4
5
6
MODEL NO.
CONFIGURED USING CRIMSON
LATER)
UP TO 5 RS-232/422/485 COMMUNICATIONS PORTS
(2 RS-232 AND 1 RS-422/485 ON BOARD, 1 RS-232 AND 1
RS-422/485 ON OPTIONAL COMMUNICATIONS CARD)
10 BASE T/100 BASE-TX ETHERNET PORT TO NETWORK UNITS
AND HOST WEB PAGES (2
G308A2 ONLY)
USB PORT TO DOWNLOAD THE UNIT’S CONFIGURATION FROM
A PC OR FOR DATA TRANSFERS TO A PC
UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE
MEMORY (32MBYTE FLASH)
COMPACTFLASH
7.5" OR 8.4-INCH TFT 32K VGA 640X480 PIXEL LCD
7-BUTTON KEYPAD FOR ON-SCREEN MENUS
THREE FRONT PANEL LEDS
POWER UNIT FROM 24VDC ±20% SUPPLY
RESISTIVE ANALOG TOUCHSCREEN
G3PBDP
GSGSM
Contact your Red Lion distributor or visit our website for complete selection.
Red Lion offers RJ modular jack adapters. Refer to the DR literature for complete
Battery type is lithium coin type CR2025
- G308 Operator Interface.
- Panel Gasket.
- This hardware bulletin.
- Template for panel cutout.
- Hardware packet for mounting unit into panel.
- Terminal block for connecting power.
SFCRM
G3FILM
Use this part number to purchase Crimson on CD with a printed manual, USB
cable, and RS-232 cable. Otherwise, download for free from www.redlion.net.
separately if needed.
details.
Industrial grade two million write cycles. SMART Modular Technologies model
SG9CF (UL Listed Directory Category NWGQ).
Antenna (G3QANT00) is NOT included with the card. Must be purchased
G3RS
G3CN
G3DN
G3CF
G308
CBL
DR
7.5" TFT Display Operator Interface (indoor),
No USB Host, non-isolated comms
8.4" TFT Display Operator Interface (indoor),
USB Host, Isolated Comms
8.4" TFT Display Operator Interface (indoor),
Dual Ethernet, USB Host, Isolated Comms
CompactFlash Card
RS 232/485 Optional Communication Card
CANopen Optional Communication Card
DeviceNet Optional Communication Card
Profibus DP Optional Communication Card
GSM/GPRS Modem Option Card
Crimson
RS-232 Programming Cable
USB Cable
Communications Cables
DIN Rail Mountable Adapter Products
Replacement Battery
G308A Backlight Replacement
Protective Films
®
2
SOCKET TO INCREASE MEMORY CAPACITY
DESCRIPTION
ND
6
5
ETHERNET PORT OPTIONAL-
1
®
SOFTWARE (VERSION 2.0 OR
3
4
Bulletin No. G308C-C
Drawing No. LP0808
Released 05/10
PART NUMBER
CBLPROG0
G3GSM000
G3PBDP00
CBLUSB00
G3RS0000
G3CN0000
G3DN0000
G3BR08A0
G308C100
G308A210
G308A230
G3CFxxxx
BNL20000
G3FILM08
CBLxxxxx
DRxxxxxx
SFCRM

Related parts for G308A210

G308A210 Summary of contents

Page 1

... Battery type is lithium coin type CR2025 6 Industrial grade two million write cycles. SMART Modular Technologies model SG9CF (UL Listed Directory Category NWGQ). 1 Bulletin No. G308C-C Drawing No. LP0808 Released 05/10 PART NUMBER G308C100 G308A210 G308A230 G3CFxxxx G3RS0000 G3CN0000 G3DN0000 G3PBDP00 3 G3GSM000 SFCRM CBLPROG0 CBLUSB00 ...

Page 2

S PECIFICATIONS 1. POWER REQUIREMENTS: G308C1: +24 VDC ±20 maximum. G308A2: +24 VDC ±20 maximum. Must use NEC Class 2 or Limited Power source (LPS) rated power supply. Power connection via removable three position ...

Page 3

I NSTALLING AND MOUNTING INSTRUCTIONS This operator interface is designed for through-panel mounting. A panel cut- out diagram and a template are provided. Care should be taken to remove any loose material from the mounting cut-out to prevent that material ...

Page 4

... In order to access data from the CompactFlash card via the USB device port, a driver must be installed on your computer. This driver is installed with Crimson and is located in the folder C:\Program Files\Red Lion Controls\ Crimson 2.0\Device\ after Crimson is installed. This may have already been accomplished if your G308 was configured using the USB port. ...

Page 5

CONNECTING A G308 OPERATOR INTERFACE TO AN ICM5 ICM5 DIP Switch Settings Application Dependent RS422/485 COMMS PORT The G308 has one RS422/485 port. The G308A port is isolated, while the G308C port is not isolated. This port can be configured ...

Page 6

S /U OFTWARE NIT CRIMSON SOFTWARE Crimson software is available as a free download from Red Lion’s website or it can be purchased on a CD, see “Ordering Information” for part number. The latest version of the software is always ...

Page 7

BATTERY & TIME KEEPING WARNING - EXPLOSION HAZARD - THE AREA MUST BE KNOWN TO BE NON-HAZARDOUS BEFORE SERVICING/ REPLACING THE UNIT AND BEFORE INSTALLING OR REMOVING I/O WIRING AND BATTERY. WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT ...

Page 8

... Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P ...

Related keywords