HIN202ECBZ-T Intersil, HIN202ECBZ-T Datasheet - Page 11

no-image

HIN202ECBZ-T

Manufacturer Part Number
HIN202ECBZ-T
Description
IC 2DRVR/2RCVR RS232 5V 16-SOIC
Manufacturer
Intersil
Type
Transceiverr
Datasheet

Specifications of HIN202ECBZ-T

Package / Case
16-SOIC (0.300", 7.5mm Width)
Mounting Type
Surface Mount
Voltage - Supply
4.5 V ~ 5.5 V
Number Of Drivers/receivers
2/2
Protocol
RS232
Rohs Compliant
YES
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
HIN213E Operation in Shutdown
The HIN213E features two receivers, R4 and R5, which
remain active in shutdown mode. During normal operation
the receivers propagation delay is typically 0.5µs. This
propagation delay may increase slightly during shutdown.
When entering shut down mode, receivers R4 and R5 are
not valid for 80µs after SD = V
mode, all receiver outputs will be invalid until the charge
pump circuitry reaches normal operating voltage. This is
typically less than 2ms when using 0.1µF capacitors.
R
T
-30V < R
OR
OUT
FIGURE 6. PROPAGATION DELAY DEFINITION
OUT
R
T
OR
IN
IN
AVERAGE PROPAGATION DELAY =
XIN
t
PHL
R
GND
V
XIN
HIN202E, HIN206E, HIN207E, HIN208E, HIN211E, HIN213E, HIN232E
CC
< +30V
FIGURE 5. RECEIVER
5kΩ
11
IL
t
PLH
. When exiting shutdown
GND < V
t
PHL +
R
ROUT
OUT
2
t
PLH
< V
CC
V
V
OL
OL
Application Information
The HIN2XXE may be used for all RS-232 data terminal and
communication links. It is particularly useful in applications
where ±12V power supplies are not available for
conventional RS-232 interface circuits. The applications
presented represent typical interface configurations.
A simple duplex RS-232 port with CTS/RTS handshaking is
illustrated in Figure 7. Fixed output signals such as DTR
(data terminal ready) and DSRS (data signaling rate select)
is generated by driving them through a 5kΩ resistor
connected to V+.
In applications requiring four RS-232 inputs and outputs
(Figure 8), note that each circuit requires two charge pump
capacitors (C1 and C2) but can share common reservoir
capacitors (C3 and C4). The benefit of sharing common
reservoir capacitors is the elimination of two capacitors and
the reduction of the charge pump source impedance which
effectively increases the output swing of the transmitters.
TTL/CMOS
OUTPUTS
FIGURE 7. SIMPLE DUPLEX RS-232 PORT WITH CTS/RTS
INPUTS
0.1µF
0.1µF
C1
C2
+5V
RTS
CTS
RD
TD
+
+
-
-
HANDSHAKING
11
10
12
1
3
4
5
9
R2
HIN232E
15
T1
16
R1
T2
14
13
6
7
8
+
-
+
-
TD (2) TRANSMIT DATA
RTS (4) REQUEST TO SEND
RD (3) RECEIVE DATA
CTS (5) CLEAR TO SEND
SIGNAL GROUND (7)
RS-232
INPUTS AND OUTPUTS
CTR (20) DATA
TERMINAL READY
DSRS (24) DATA
SIGNALING RATE
SELECT
November 4, 2005
FN4315.16

Related parts for HIN202ECBZ-T