178803-3 TE Connectivity, 178803-3 Datasheet - Page 11

3.81 DYNAMIC CAP HSG PANEL 6P

178803-3

Manufacturer Part Number
178803-3
Description
3.81 DYNAMIC CAP HSG PANEL 6P
Manufacturer
TE Connectivity
Datasheets

Specifications of 178803-3

Product Type
Connector
Connector Type
Housing
Mount
Panel
Keyed
No
Product Series
D-3100D
Voltage Rating (vac)
250
Number Of Positions
6
Number Of Rows
2
Contact Type
Pin
Connector Style
Plug
Housing Material
Thermoplastic - GF
Ul Flammability Rating
UL 94V-0
Housing Color
Black
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Applies To
Wire/Cable
Packaging Quantity
250
Packaging Method
Bag

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
178803-3
Manufacturer:
N/A
Quantity:
38 417
Part Number:
178803-3
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
950
Part Number:
178803-3
Manufacturer:
MOLEX
Quantity:
35 000
4.品質保証条項
Rev. J5
4.1 製品認定試験
4.2 製品再認定試験
C.試験条件
A.試料の選定
B.試験順序
もし製品に、形状、組合せや嵌合、又は機能に
相当の影響を及ぼす変更がなされた時には、品
保証部門は、製品開発、品質保証、信頼性技術
部門により決定された初期の試験項目全部又は
その一部による製品再認定試験の実施を設定す
ること。
もとで性能試験を行うものとする。
コネクタとコンタクトは該当する取扱説明書
に従って作成準備されること。試料は現行の生
産システムから無作為抽出で選定されること。
品質確認検査はFig.6に示す順序で試験を実施
し、性能要件を確かめること。
特に指定のない場合は、下記に示す環境条件の
気 圧/Atmospheric Pressure
相対湿度/Relative humidity
温 度/Temperature
Product Specification
製品規格
4.QUALITY ASSURANCE ROVISIONS:
4.1 Qualification Testing:
866.6~1066.6hPa
4.2
A.Sample Selection:
B.Test Sequence:
C.Test Conditions:
If changes sighificantly affecting from、fit,or
function are made to the product or to the
manufacturing process,product assurance shall
coordinate requalification testing,consisting
of all or part of the original testing sequence
as determined by envelopment product,quality,
and reliability engineering.
Connector housings and contacts shall be
prepared in accordance with applicable
Instruction Sheets. They shall be selected
at random from current production.
Qualification inspection shall be verified by
Testing samples as specified in Figure 6.
Unless otherwise specified,all the tests
shall be performed in any conbination of the
test condition.
Requalification Testing
15~35℃
45~75%
108-5349
11 of 12