120788-1 TE Connectivity, 120788-1 Datasheet - Page 6

High Speed / Modular Connectors REC 6X005P R/A LT B-PLANE HS3

120788-1

Manufacturer Part Number
120788-1
Description
High Speed / Modular Connectors REC 6X005P R/A LT B-PLANE HS3
Manufacturer
TE Connectivity
Series
120788r
Datasheets

Specifications of 120788-1

Number Of Rows
6
Number Of Positions / Contacts
30
Pitch
2 mm
Mounting Style
Through Hole
Termination Style
Solder Pin
Housing Material
Glass Filled Polyester
Contact Material
Copper Alloy
Contact Plating
Gold
Product Type
Connector
Connector Type
Connector Assembly
Pcb Mounting Orientation
Right Angle
Module Type
Right
Solder Tail Contact Plating
Tin-Lead over Nickel
Termination Post Length (mm [in])
2.27 [0.089]
Card Slot Pitch (mm [in])
25.4 [1]
Rows Per Connector
6
Columns Per Connector
5
Number Of Signal Contacts
30
Centerline (mm [in])
2.00 [0.079]
Contact Type
Socket
Contact Style
Press Fit, Short Tail
Guide Pin Style
ESD/HDI
Contact Base Material
Copper Alloy
Contact Plating, Mating Area, Material
Conforms to Performance Requirements of TE Connectivity Product Specification 108-1957; Based on Telcordia GR-1217-CORE, Applications in Uncontrolled Environments
Connector Style
Receptacle
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Lead Free Status / Rohs Status
 Details
4.
4.1.
4.2.
4.3.
4.4.
Rev C
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form, fit or function are made to the product or manufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determined by development/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product meets the requirements of Figure 1. Failures
attributed to equipment, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to
confirm corrective action is required before resubmittal.
Quality Conformance Inspection
The applicable quality inspection plan shall specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing
and this specification.
Specimen Selection
Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. All test groups shall each consist of a minimum of 5
specimens.
Test Sequence
Qualification inspection shall be verified by testing specimens as specified in Figure 2.
108-1957
6 of 7

Related parts for 120788-1