Specifications of ATMEGA328P-20PU

Cpu Family
ATmega
Device Core
AVR
Device Core Size
8b
Frequency (max)
20MHz
Interface Type
SPI/TWI/USART
Program Memory Type
Flash
Program Memory Size
32KB
Total Internal Ram Size
2KB
# I/os (max)
23
Number Of Timers - General Purpose
3
Operating Supply Voltage (typ)
3.3/5V
Operating Supply Voltage (max)
5.5V
Operating Supply Voltage (min)
2.7V
On-chip Adc
6-chx10-bit
Instruction Set Architecture
RISC
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Through Hole
Pin Count
28
Package Type
PDIP
Lead Free Status / Rohs Status
Compliant
27.7
27.7.1
8025K–AVR–10/09
Parallel Programming
Enter Programming Mode
Table 27-13. XA1 and XA0 Coding
Table 27-14. Command Byte Bit Coding
The following algorithm puts the device in Parallel (High-voltage) Programming mode:
1. Set Prog_enable pins listed in
2. Apply 4.5 - 5.5V between V
Ensure that V
3. Wait 20 - 60 µs, and apply 11.5 - 12.5V to RESET.
4. Keep the Prog_enable pins unchanged for at least 10µs after the High-voltage has been
5. Wait at least 300 µs before giving any parallel programming commands.
6. Exit Programming mode by power the device down or by bringing RESET pin to 0V.
If the rise time of the V
tive algorithm can be used.
1. Set Prog_enable pins listed in
2. Apply 4.5 - 5.5V between V
3. Monitor V
Command Byte
XA1
V
applied to ensure the Prog_enable Signature has been latched.
V
0
0
1
1
CC
CC
1000 0000
0100 0000
0010 0000
0001 0000
0001 0001
0000 1000
0000 0100
0000 0010
0000 0011
to 0V.
to 0V.
CC
CC
XA0
0
1
0
1
, and as soon as V
reaches at least 1.8V within the next 20 µs.
Action when XTAL1 is Pulsed
Load Flash or EEPROM Address (High or low address byte determined by BS1).
Load Data (High or Low data byte for Flash determined by BS1).
Load Command
No Action, Idle
Command Executed
Chip Erase
Write Fuse bits
Write Lock bits
Write Flash
Write EEPROM
Read Signature Bytes and Calibration byte
Read Fuse and Lock bits
Read Flash
Read EEPROM
CC
is unable to fulfill the requirements listed above, the following alterna-
CC
CC
Table 27-12 on page 295
and GND.
Table 27-12 on page 295
and GND.
CC
reaches 0.9 - 1.1V, apply 11.5 - 12.5V to RESET.
ATmega48P/88P/168P
to “0000”, RESET pin to 0V and
to “0000”, RESET pin to 0V and
296