ISP1761BE STEricsson, ISP1761BE Datasheet - Page 73

no-image

ISP1761BE

Manufacturer Part Number
ISP1761BE
Description
Manufacturer
STEricsson
Datasheet

Specifications of ISP1761BE

Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Operating Temperature (max)
85C
Package Type
LQFP
Rad Hardened
No
Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISP1761BE
Manufacturer:
ST
0
Part Number:
ISP1761BE
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
ISP1761BE
Quantity:
56
Company:
Part Number:
ISP1761BE
Quantity:
1 000
Part Number:
ISP1761BE-S
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Part Number:
ISP1761BEGE
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Part Number:
ISP1761BEUM
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
NXP Semiconductors
Table 68.
ISP1761_5
Product data sheet
Bit
30 to 29 Mult[1:0]
28 to 18 MaxPacket
17 to 3
2 to 1
0
Symbol
Length[10:0]
NrBytesTo
Transfer[14:0]
reserved
V
High-speed interrupt IN and OUT: bit description
Table 69.
b
1
2
3
4
5
6
7
8
9
Access
SW — writes
SW — writes
SW — writes
-
SW — sets
HW — resets
Microframe description
Rate
1 SOF
2 SOF
4 SOF
1 ms
2 ms
4 ms
8 ms
16 ms
32 ms
Value Description
-
-
-
-
-
Rev. 05 — 13 March 2008
Multiplier: This field is a multiplier counter used by the host controller
as the number of successive packets the host controller may submit
to the endpoint in the current execution.
Set this field to 01b. You can also set it to 11b and 10b depending on
your application. 00b is undefined.
Maximum Packet Length: This field indicates the maximum number
of bytes that can be sent to or received from the endpoint in a single
data packet.
Number of Bytes to Transfer: This field indicates the number of
bytes that can be transferred by this data structure. It is used to
indicate the depth of the DATA field (32 kB
-
Valid:
0 — This bit is deactivated when the entire PTD is executed, or when
a fatal error is encountered.
1 — Software updates to one when there is payload to be sent or
received. The current PTD is active.
0 0000
0 0000
0 0000
0 0000
0 0001
0 0010 to 0 0011
0 0100 to 0 0111
0 1000 to 0 1111
1 0000 to 1 1111
Frame[7:3]
…continued
1111 1111
1010 1010 or 0101 0101
any 2 bits set
any 1 bit set
any 1 bit set
any 1 bit set
any 1 bit set
any 1 bit set
any 1 bit set
SA[7:0]
Hi-Speed USB OTG controller
1 B).
© NXP B.V. 2008. All rights reserved.
ISP1761
72 of 163

Related parts for ISP1761BE