ES-FA-11AA BANNER ENGINEERING, ES-FA-11AA Datasheet
ES-FA-11AA
Specifications of ES-FA-11AA
Related parts for ES-FA-11AA
ES-FA-11AA Summary of contents
Page 1
... S21-S22 The ES-FA-9AA has three normally open output switching channels for connection to control-reliable power interrupt circuits The ES-FA-11AA has two normally open output switching channels for connection to control-reliable power interrupt circuits and one normally closed auxiliary output channel Automatic reset or monitored manual reset Design complies with standards ANSI B11 ...
Page 2
... This Safety Module data sheet (p/n 60606) satisfies the requirements of Machinery Directive 2006/42/EC, Section 1.7.4 — instructions. 2 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-FA-9AA / ES-FA-11AA E-Stop Safety Modules Applicable International Standards ISO 12100-1 (EN292-1) Safety of Machinery – Basic Concepts, General Principles for Design, Part 1: Basic Terminology, Methodology ISO 12100-2 (EN292-2) Safety of Machinery – ...
Page 3
... An Emergency Stop Safety Module is used to increase the control relia- bility of an emergency stop circuit. As shown in the hookup drawings, the models ES-FA-9AA and ES-FA-11AA E-Stop Safety Modules are designed to monitor a 1-channel or 2-channel E-stop switch. A 2-channel E-stop switch has two electrically isolated contacts. ...
Page 4
... Actuators of emergency-stop devices shall be colored red.The background immediately around the device actuator shall be colored yellow (where possible). The actuator of a push-button-operated device shall be of the palm or mushroom-head type. The emergency-stop actuator shall be a self-latching type. 4 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-FA-9AA / ES-FA-11AA E-Stop Safety Modules Tel: 763.544.3164 P/N 060606 rev. E ...
Page 5
... ES-FA-9AA / ES-FA-11AA E-Stop Safety Modules For Rope/Cable Pull installations only: The wire rope should be easily accessible and visible along its entire length. Markers or flags may be fixed on the rope to increase its visibility. Mounting points, including support points, must be rigid. The rope should be free of friction at all supports. Pulleys are recommended. ...
Page 6
... If you have any questions about your intended use, please contact a Banner applications engineer at the numbers listed on the last page. 6 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-FA-9AA / ES-FA-11AA E-Stop Safety Modules Tel: 763.544.3164 P/N 060606 rev. E ...
Page 7
... Failure to test each switch individually in this manner could result in undetected faults and create an unsafe condition which could result in serious injury or death. This check must be performed during periodic checkouts. Connection of Safety Switches Models ES-FA-9AA and ES-FA-11AA may be used to monitor safety interlocking switches that determine the position of a guard or gate. To achieve Category 4 operation per ISO 13849-1 (EN 954-1), two positive-opening safety switches must operate con- currently when the guard or gate is opened (see figure at right) ...
Page 8
... Safety Module to normalize, allowing a reliable reset to occur. A lockout will occur if the Module is cycled too quickly. To clear the lockout, the Module must be re- cycled, meeting the minimum OFF time requirements. 8 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-FA-9AA / ES-FA-11AA E-Stop Safety Modules Tel: 763.544.3164 P/N 060606 rev. E ...
Page 9
... ES-FA-9AA / ES-FA-11AA E-Stop Safety Modules Figure 4: Hookup; Dual-channel E-stop applications Figure 5: Hookup; Single-channel E-stop applications P/N 060606 rev. E Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com Tel: 763.544.3164 9 ...
Page 10
... Safety Module terminals S31 and S32. 10 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-FA-9AA / ES-FA-11AA E-Stop Safety Modules Tel: 763.544.3164 P/N 060606 rev. E ...
Page 11
... ES-FA-9AA / ES-FA-11AA E-Stop Safety Modules WARNING . . . Wiring of Arc Suppressors If arc suppressors are used, they MUST be installed as shown across the actuator coil of the master stop control elements (MSC1 to MSC3). NEVER install suppressors directly across the output contacts of the Safety Module possible for suppressors to fail as a short circuit. If installed directly across the output contacts of the Safety Module, a short-circuited suppressor will create an unsafe condition which could result in se- rious injury or death ...
Page 12
... Contact Banner Factory Application Engineering at the address or the numbers listed on the back page. They will attempt to troubleshoot the system from your description of the problem. If they conclude that a component is defective, 12 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-FA-9AA / ES-FA-11AA E-Stop Safety Modules Periodic Checkout Procedure Repairs Tel: 763.544.3164 ...
Page 13
... Each normally open output channel is a series connection of contacts from two forced-guided (mechanically linked) relays, K1-K2. The normally closed Aux. output channel of the ES-FA-11AA is a parallel connection of contacts from two forced- guided relays, K1-K2. Contacts: AgNi, 5 µm gold-plated Low Current Rating: The 5 µm gold-plated contacts allow the switching of low current/low voltage. In these low-power applications, multiple contacts can also be switched in series (e.g., “ ...
Page 14
... Cat per EN ISO 13849-1; SIL 3 per IEC 61508 and IEC 62061 Certifications 14 Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com ES-FA-9AA / ES-FA-11AA E-Stop Safety Modules Dual-Channel (contacts) hookup – steady state @ 12V dc NOTE: Inputs are designed with a brief contact-cleaning current of 100 mA when initially closed. ...
Page 15
... ES-FA-9AA / ES-FA-11AA E-Stop Safety Modules Figure 7: Dimensions — (inches) S21 A1 Power Ch S22 Figure 8: Product label — model ES-FA-9AA shown P/N 060606 rev. E Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com S33 S11 ES-FA-9AA S34 S12 Tel: 763.544.3164 15 ...
Page 16
... Banner Enginering Corp. 9714 Tenth Avenue North Minneapolis, MN 55441-5019 USA We herewith declare that ES-FA-9AA and ES-FA-11AA Emergency Stop Modules for industrial control are in conformity with the provisions of the Machinery Directive (Directive 98/37/EEC), and all essential Health and Safety Requirements have been met. ...