SI3019-F-FT Silicon Laboratories Inc, SI3019-F-FT Datasheet - Page 83

no-image

SI3019-F-FT

Manufacturer Part Number
SI3019-F-FT
Description
IC VOICE DAA GCI/PCM/SPI 16TSSOP
Manufacturer
Silicon Laboratories Inc
Type
Chipsetr
Datasheets

Specifications of SI3019-F-FT

Package / Case
16-TSSOP
Function
Data Access Arrangement (DAA)
Interface
GCI, PCM, SPI
Number Of Circuits
1
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
8.5mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Includes
Line Voltage Monitor, Loop Current Monitor, Overload Detection, Parallel Handset Detection, Polarity Reversal Detection, TIP and
Product
Modem Chip
Supply Voltage (min)
3 V
Supply Current
8.5 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3019-F-FTR
Manufacturer:
SiliconL
Quantity:
5 000
Part Number:
SI3019-F-FTR
Manufacturer:
SiliconLa
Quantity:
872
Part Number:
SI3019-F-FTR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Register 32. Ground Start Control
Reset settings = 0000_0x11
Bit
7:3
2
1
0
Name
Type
Bit
Reserved
TGDE
Name
TGD
RG
D7
TIP Ground Detect.
0 = The CO has grounded TIP, causing current to flow. When current ceases to flow, this bit
returns to a one.
1 = The CO has not grounded TIP causing current to flow.
TIP Ground Detect Enable.
0 = The external relay connecting TIP to an isolated supply is closed, enabling current to flow
in TIP if the CO grounds TIP.
1 = The external relay connecting TIP to an isolated supply is open. In this state, the DAA is
unable to determine if the CO has grounded TIP.
Ring Ground.
0 = The external relay connecting RING to ground is closed, causing current to flow in RING.
1 = The external relay connecting RING to ground is open, not allowing current to flow in
RING.
Read returns zero.
D6
D5
Rev. 1.2
D4
Function
D3
TGD
D2
R
TGDE
D1
W
Si3050
RG
D0
W
83