Specifications of PEB 3081 H V1.4

Function
S / T Bus Interface Transceiver
Interface
IOM-2, ISDN, SCI
Number Of Circuits
1
Voltage - Supply
3.3V
Current - Supply
30mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
64-QFP
Includes
D-Channel Access Control, Monitor Channel Handler
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB3081HV1.4XT
PEB3081HV14XP
SP000007583
SP000007584
CIX1
TR_
CONF0
4.1.5
Value after reset: FE
CODX1 ... C/I-Code 1 Transmit
Bits 7-2 of C/I-channel 1 timeslot.
CICW... C/I-Channel Width
CICW selects between a 4 bit (’0’) and 6 bit (’1’) C/I1 channel width.
The C/I1 handler always reads and writes 6-bit values but if 4-bit is selected, the higher
two bits are ignored for interrupt generation. However in write direction the full CODX1
code is transmitted, i.e. the host must write the higher two bits to “1”.
CI1E ... C/I-Channel 1 Interrupt Enable
Interrupt generation ISTA.CIC of CIR0.CIC1 is enabled (1) or masked (0).
4.1.6
Value after reset: 01
DIS_TR ... Disable Transceiver
Setting DIS_TR to “1” disables the transceiver. In order to reenable the transceiver
again, a transceiver reset must be issued (SRES.RES_TR = 1). The transceiver must
not be reenabled by setting DIS_TR from “1” to “0”.
For general information please refer to
BUS ... Point-to-Point / Bus Selection (NT/LT-S/Int. NT mode only)
0: Adaptive Timing (Point-to-Point, extended passive bus).
1: Fixed Timing (Short passive bus).
Data Sheet
7
7
CIX1 - Command/Indication Transmit 1
TR_CONF0 - Transceiver Configuration Register 0
DIS_
TR
BUS
H
H
EN_
ICV
CODX1
0
Chapter
129
L1SW
3.3.9.
0
Detailed Register Description
CICW CI1E
EXLP
0
0
LDD
RD/WR (30)
PEB 3081
2003-02-04
SBCX-X
WR (2F)