PEB 3081 H V1.4 Infineon Technologies, PEB 3081 H V1.4 Datasheet - Page 73

no-image

PEB 3081 H V1.4

Manufacturer Part Number
PEB 3081 H V1.4
Description
IC S-BUS INTERFACE EXT MQFP44
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB 3081 H V1.4

Function
S / T Bus Interface Transceiver
Interface
IOM-2, ISDN, SCI
Number Of Circuits
1
Voltage - Supply
3.3V
Current - Supply
30mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
64-QFP
Includes
D-Channel Access Control, Monitor Channel Handler
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power (watts)
-
Other names
PEB3081HV1.4XT
PEB3081HV14XP
SP000007583
SP000007584
G4 Pending Deactivation
This state is triggered by a deactivation request DR, and is an unstable state. Indication
DI (state “G4 wait for DR”) is issued by the transceiver when:
either INFO 0 is received for a duration of 16 ms
or an internal timer of 32 ms expires.
G4 wait for DR
Final state after a deactivation request. The transceiver remains in this state until DC is
issued.
Unconditional States
Test Mode SSP
Send Single Pulses
Test Mode SCP
Send Continuous Pulses
3.5.3.3
Command
Deactivation
Request
Reset
Send Single Pulses
Send Continuous
Pulses
Receiver not
Synchronous
Activation Request
Activation Request
Loop
Data Sheet
C/I Codes (NT)
AR
Abbr.
DR
RES
SSP
SCP
RSY
ARL
Code
0000
0001
0010
0011
0100
1000
1010
Send Continuous Pulses.
Remark
DR - Deactivation Request. Initiates a complete
deactivation from the exchange side by
transmitting INFO 0. Unconditional command.
Reset of state machine. Transmission of
INFO 0. No reaction to incoming infos. RES is
an unconditional command.
Send Single Pulses.
Receiver is not synchronous
Activation Request. This command is used to
start an exchange initiated activation.
Activation request loop. The transceiver is
requested to operate an analog loop-back close
to the S/T-interface.
73
Description of Functional Blocks
PEB 3081
2003-02-04
SBCX-X