ADUM2201BRIZ Analog Devices Inc, ADUM2201BRIZ Datasheet

no-image

ADUM2201BRIZ

Manufacturer Part Number
ADUM2201BRIZ
Description
63T8602
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADUM2201BRIZ

No. Of Channels
2
Propagation Delay
50ns
Supply Current
2.6mA
Supply Voltage Range
3V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +105°C
FEATURES
High isolation voltage: 5000 V rms
Enhanced system-level ESD performance per IEC 61000-4-x
Low power operation
Bidirectional communication
3 V/5 V level translation
High temperature operation: 105°C
High data rate: dc to 10 Mbps (NRZ)
Precise timing characteristics
High common-mode transient immunity: >25 kV/μs
16-lead SOIC wide body package (RoHS-compliant
Safety and regulatory approvals
APPLICATIONS
General-purpose, high voltage, multichannel isolation
Medical equipment
Power supplies
RS-232/RS-422/RS-485 transceiver isolation
GENERAL DESCRIPTION
The ADuM220x
Devices, Inc., iCoupler® technology. Combining high speed CMOS
and monolithic air core transformer technology, these isolation
components provide outstanding performance characteristics that
are superior to alternatives such as optocoupler devices.
By avoiding the use of LEDs and photodiodes, iCoupler devices
remove the design difficulties commonly associated with opto-
couplers. Typical optocoupler concerns regarding uncertain
current transfer ratios, nonlinear transfer functions, and temper-
ature and lifetime effects are eliminated with the simple iCoupler
digital interfaces and stable performance characteristics. The
Rev. A
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
5 V operation
3 V operation
3 ns maximum pulse width distortion
3 ns maximum channel-to-channel matching
models available)
UL recognition: 5000 V rms for 1 minute per UL 1577
CSA Component Acceptance Notice #5A
VDE certificate of conformity
1.6 mA per channel maximum @ 0 Mbps to 2 Mbps
3.7 mA per channel maximum @ 10 Mbps
1.4 mA per channel maximum @ 0 Mbps to 2 Mbps
2.4 mA per channel maximum @ 10 Mbps
IEC 60950-1: 600 V rms (reinforced)
IEC 60601-1: 250 V rms (reinforced)
DIN V VDE V 0884-10 (VDE V 0884-10):2006-12
V
IORM
= 846 V peak
1
are 2-channel digital isolators based on Analog
Dual-Channel Digital Isolators, 5 kV
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
Fax: 781.461.3113
need for external drivers and other discrete components is elimi-
nated with these iCoupler products. Furthermore, iCoupler
devices run at one-tenth to one-sixth the power of optocouplers
at comparable signal data rates.
The ADuM220x isolators provide two independent isolation
channels in a variety of channel configurations and data rates
(see the Ordering Guide). The ADuM220x models operate with
the supply voltage of either side ranging from 3.0 V to 5.5 V,
providing compatibility with lower voltage systems as well as
enabling voltage translation functionality across the isolation
barrier. The ADuM220x isolators have a patented refresh feature
that ensures dc correctness in the absence of input logic transi-
tions and during power-up/power-down conditions.
Similar to the ADuM320x isolators, the ADuM220x isolators
contain various circuit and layout enhancements to provide
increased capability relative to system-level IEC 61000-4-x
testing (ESD, burst, and surge). The precise capability in these
tests for either the ADuM320x or ADuM220x products is strongly
determined by the design and layout of the user’s board or
module. For more information, see the AN-793 Application Note,
ESD/Latch-Up Considerations with iCoupler Isolation Products.
1
Protected by U.S. Patents 5,952,849; 6,873,065; 6,903,578; and 7,075,329.
Other patents pending.
GND
GND
GND
GND
V
V
V
DD1
DD1
V
V
V
NC
NC
NC
NC
NC
NC
OA
IA
IB
IB
1
1
1
1
FUNCTIONAL BLOCK DIAGRAMS
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
NC = NO CONNECT
NC = NO CONNECT
ADuM2200/ADuM2201
PIN 1
INDICATOR
PIN 1
INDICATOR
ENCODE
ENCODE
DECODE
ENCODE
©2008 Analog Devices, Inc. All rights reserved.
Figure 1. ADuM2200
Figure 2. ADuM2201
ADuM2200
ADuM2201
DECODE
DECODE
ENCODE
DECODE
www.analog.com
16
15
14
13
12
11
10
16
15
14
13
12
11
10
9
9
GND
NC
V
V
V
NC
NC
GND
GND
NC
V
V
V
NC
NC
GND
DD2
OA
OB
DD2
IA
OB
2
2
2
2

Related parts for ADUM2201BRIZ

ADUM2201BRIZ Summary of contents

Page 1

... V to 5.5 V, providing compatibility with lower voltage systems as well as enabling voltage translation functionality across the isolation barrier. The ADuM220x isolators have a patented refresh feature that ensures dc correctness in the absence of input logic transi- tions and during power-up/power-down conditions. ...

Page 2

ADuM2200/ADuM2201 TABLE OF CONTENTS Features .............................................................................................. 1 Applications ....................................................................................... 1 General Description ......................................................................... 1 Functional Block Diagrams ............................................................. 1 Revision History ............................................................................... 2 Specifications ..................................................................................... 3 Electrical Characteristics—5 V Operation................................ 3 Electrical Characteristics—3 V Operation................................ 5 Electrical Characteristics—Mixed 5 V/3 ...

Page 3

SPECIFICATIONS ELECTRICAL CHARACTERISTICS—5 V OPERATION 4.5 V ≤ V ≤ 5.5 V, 4.5 V ≤ V ≤ 5.5 V. All minimum/maximum specifications apply over the entire recommended operation range, DD1 DD2 unless otherwise noted. All typical specifications are at T ...

Page 4

ADuM2200/ADuM2201 Parameter ADuM220xBR 3 Minimum Pulse Width 4 Maximum Data Rate 5 Propagation Delay Pulse Width Distortion, |t − PLH PHL Change vs. Temperature 6 Propagation Delay Skew Channel-to-Channel Matching, 7 Codirectional Channels Channel-to-Channel Matching, 7 Opposing ...

Page 5

ELECTRICAL CHARACTERISTICS—3 V OPERATION 3.0 V ≤ V ≤ 3.6 V, 3.0 V ≤ V ≤ 3.6 V. All minimum/maximum specifications apply over the entire recommended operation range, DD1 DD2 unless otherwise noted. All typical specifications are at T Table ...

Page 6

ADuM2200/ADuM2201 Parameter ADuM220xBR 3 Minimum Pulse Width 4 Maximum Data Rate 5 Propagation Delay Pulse Width Distortion, |t − PLH PHL Change vs. Temperature 6 Propagation Delay Skew Channel-to-Channel Matching, 7 Codirectional Channels Channel-to-Channel Matching, 7 Opposing Directional ...

Page 7

ELECTRICAL CHARACTERISTICS—MIXED 5 V V/5 V OPERATION 5 V/3 V operation: 4.5 V ≤ V ≤ 5.5 V, 3.0 V ≤ V DD1 minimum/maximum specifications apply over the entire recommended operation range, unless otherwise noted. All typical ...

Page 8

ADuM2200/ADuM2201 Parameter For All Models Input Currents Logic High Input Threshold Logic Low Input Threshold Logic High Output Voltages Logic Low Output Voltages SWITCHING SPECIFICATIONS ADuM220xAR 3 Minimum Pulse Width 4 Maximum Data Rate 5 Propagation Delay 5 Pulse Width ...

Page 9

Parameter Output Dynamic Supply Current, per Channel 9 5 V/3 V Operation 3 V/5 V Operation 1 All voltages are relative to their respective ground. 2 The supply current values for both channels are combined when running at identical data ...

Page 10

ADuM2200/ADuM2201 PACKAGE CHARACTERISTICS Table 4. Parameter 1 Resistance (Input-to-Output) 1 Capacitance (Input-to-Output) 2 Input Capacitance IC Junction-to-Case Thermal Resistance, Side 1 IC Junction-to-Case Thermal Resistance, Side 2 1 Device considered a 2-terminal device: Pin 1 through Pin 8 are shorted ...

Page 11

... DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by means of protective circuits. Note that the asterisk (*) branded on packages denotes DIN V VDE V 0884-10 approval for 846 V peak working voltage ...

Page 12

ADuM2200/ADuM2201 ABSOLUTE MAXIMUM RATINGS Table 9. Parameter Storage Temperature ( Ambient Operating Temperature ( Supply Voltage ( DD1 DD2 1, 2 Input Voltage ( ...

Page 13

PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS Table 13. ADuM2200 Pin Function Descriptions Pin No. Mnemonic Description 1 GND Ground 1. Ground reference for Isolator Side internal connection Supply Voltage for Isolator Side 1, 3.0 ...

Page 14

ADuM2200/ADuM2201 Table 14. ADuM2201 Pin Function Descriptions Pin No. Mnemonic Description 1 GND Ground 1. Ground reference for Isolator Side internal connection Supply Voltage for Isolator Side 1, 3 5.5 V. ...

Page 15

TYPICAL PERFORMANCE CHARACTERISTICS DATA RATE (Mbps) Figure 6. Typical Input Supply Current per Channel vs. Data Rate for 5 V and 3 V Operation (No Output Load ...

Page 16

ADuM2200/ADuM2201 APPLICATIONS INFORMATION PCB LAYOUT The ADuM220x digital isolator requires no external interface circuitry for the logic interfaces. Power supply bypassing is strongly recommended at the input and output supply pins (see Figure 12). Bypass capacitors are most conveniently connected ...

Page 17

For example magnetic field frequency of 1 MHz, the maximum allowable magnetic field of 0.2 kgauss induces a voltage of 0. the receiving coil. This is about 50% of the sensing threshold and does not cause ...

Page 18

ADuM2200/ADuM2201 INSULATION LIFETIME All insulation structures eventually break down when subjected to voltage stress over a sufficiently long period. The rate of insulation degradation is dependent on the characteristics of the voltage waveform applied across the insulation. In addition to ...

Page 19

OUTLINE DIMENSIONS 0.30 (0.0118) 0.10 (0.0039) COPLANARITY 0.10 CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS (IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN. ORDERING GUIDE Number Number of Inputs, of Inputs, ...

Page 20

ADuM2200/ADuM2201 NOTES ©2008 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. D07235-0-7/08(A) Rev Page ...