UWR-12/1250-D48A Datel, Inc., UWR-12/1250-D48A Datasheet
UWR-12/1250-D48A
Related parts for UWR-12/1250-D48A
UWR-12/1250-D48A Summary of contents
Page 1
... By combining a high-frequency, high-effi ciency (to 88%), synchronous-rectifi er topology with the newest components and time-tested, fully automated, SMT-on-pcb construction, these UWR Models are able to bring you 7-15W (@ up to 6A) in the standard 2" x 1" package from which most competitors can only get 5-10W (@ 3-4A). All UWR’ ...
Page 2
... UWR-5/3000-D12A 5 3000 UWR-5/3000-D24A 5 3000 UWR-5/3000-D48A 5 3000 UWR-12/1250-D12A 12 1250 UWR-12/1250-D24A 12 1250 UWR-12/1250-D48A 12 1250 UWR-15/1000-D12A 15 1000 UWR-15/1000-D24A 15 1000 UWR-15/1000-D48A 15 1000 ➀ Typical +25°C under nominal line voltage and full-load conditions, unless otherwise noted. A ➁ Ripple/Noise (R/N) is tested/speciifed over a 20MHz bandwidth. All models are specifi ed with two external 0.47µ ...
Page 3
... Lead Temperature (soldering, 10 sec.) These are stress ratings. Exposure of devices to any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifi cations Table is not implied. 3 UWR Models Dynamic Characteristics (continued) TBD 260kHz (±30kHz) 280kHz (±30kHz) 250kHz (± ...
Page 4
... Certain applications and/or safety agencies may require the installation of fuses at the inputs of power conversion components. Fuses should also be used if the possibility of sustained, non-current-limited, input-voltage polarity reversals exists. For DATEL A-Series UWR 7-15 Watt DC/DC Converters, you should use slow-blow type fuses with values no greater than the following. V ...
Page 5
... T UP 2.49(V UWR-5/3000-D12A R (kΩ DOWN UWR-5/3000-D24A UWR-5/3000-D48A R (kΩ 6.34(V R (kΩ) = UWR-12/1250-D12A T DOWN UWR-12/1250-D24A UWR-12/1250-D48A R (kΩ 7.87(V R (kΩ) = UWR-15/1000-D12A T DOWN UWR-15/1000-D24A UWR-15/1000-D48A R (kΩ Accuracy of adjustment is subject to tolerances or resistor values and factory-adjusted output accuracy desired output voltage. ...
Page 6
... All models, other than the D12A models A (10-18 Volt input range), can operate at higher ambient temperatures if the input range is narrowed. For example, model UWR-5/3000-D48A can operate safely to +70°C if the input range is kept between 36 and 48 Volts. Contact DATEL's Applications Engineering Group if you need additional details. ...
Page 7
... Typical Performance Curves for UWR 7-15W A-Series UWR-1.5/6000-D12A Efficiency vs. Line and Load 10V 12V 18V 0.6 1.2 1.8 2.4 3 3.6 Load Current (Amps) UWR-1.5/6000-D24A Efficiency vs. Line and Load 18V 24V 36V 0.6 1.2 1.8 2.4 3 3.6 Load Current (Amps) UWR-1.5/6000-D48A Efficiency vs. Line and Load ...
Page 8
... A Series Typical Performance Curves for UWR 7-15W A-Series UWR-2.5/6000-D12A Efficiency vs. Line and Load 10V 12V 18V 0.6 1.2 1.8 2.4 3 3.6 4.2 Load Current (Amps) UWR-2.5/6000-D24A Efficiency vs. Line and Load 18V 24V 36V 0.6 1.2 1.8 2.4 3 3.6 4.2 Load Current (Amps) UWR-2 ...
Page 9
... Load Current (Amps) UWR-12/1250-D12A Efficiency vs. Line and Load 0.1 2 2.3 2.7 3 UWR-12/1250-D24A Efficiency vs. Line and Load 2.3 2.7 3 0.1 UWR-12/1250-D48A Efficiency vs. Line and Load 2.3 2.7 3 0.1 9 UWR Models V = 10V 12V 18V IN 0.2 0.4 0.5 0.7 0.8 1.0 Load Current (Amps) ...
Page 10
... A Series Typical Performance Curves for UWR 7-15W A-Series UWR-15/1000-D12A Efficiency vs. Line and Load 10V 12V 18V 0.1 0.2 0.3 0.4 0.6 0.7 Load Current (Amps) UWR-15/1000-D24A Efficiency vs. Line and Load 18V 24V 36V 0.1 0.2 0.3 0.4 0.6 0.7 Load Current (Amps) UWR-15/1000-D48A Efficiency vs ...
Page 11
... Typical Performance Curves for UWR 7-15W A-Series Output Ripple and Noise (PARD nominal 3.3V @ 4.25A, two ext. 0.47µF output capacitors.) IN OUT 20mV, 1µsec/div, 20MHz BW Output Ripple and Noise (PARD nominal 3A, two external 0.47µF output capacitors.) IN OUT 20mV, 1µsec/div, 20MHz BW ...
Page 12
... D24 = 18-36 Volts (24V nominal) D48 = 36-75 Volts (48V nominal) the pin 3 position, with adapted current limit set point to 6.5A min. and with removed Input Overvoltage Shutdown function. UWR-5/3000-D48ACT-30770 Standard product, 48V polarity) on pin 3, V Trim equations are Tyco/Lucent-compatible. Transformer isolation system has been enhanced to meet the BASIC INSULATION requirements of UL60950/EN60950 ...