Specifications of AT89C51CC03

Flash (kbytes)
64 Kbytes
Max. Operating Frequency
40 MHz
Cpu
8051-12C
Max I/o Pins
37
Spi
1
Uart
1
Can
1
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
62.5
Sram (kbytes)
2.25
Eeprom (bytes)
2048
Self Program Memory
API
Operating Voltage (vcc)
3.0 to 5.5
Timers
4
Isp
UART/CAN
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51CC03C-7CTIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC03C-IM
Manufacturer:
AT
Quantity:
17
Part Number:
AT89C51CC03C-RDRIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC03C-RLRIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC03C-RLTIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC03C-S3RIM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC03CA-IM
Manufacturer:
TI
Quantity:
18
Part Number:
AT89C51CC03CA-JM
Manufacturer:
ATEML
Quantity:
42
Part Number:
AT89C51CC03CA-RDTUM
Manufacturer:
COSMO
Quantity:
6 000
Part Number:
AT89C51CC03CA-RLTUM
Manufacturer:
ADI
Quantity:
141
Active CAN Bootloader Errata List
CAN Bootloader Errata History
CAN Bootloader Errata Description
1. Boot Process - SBV > 0x7F00 leads to Atmel bootloader execution
2. The CAN is Not Stopped
3. Watchdog and Flash API Starting the Bootloader Execution
4. Flash API ’__api_wr_code_page’ with 0 Data in Length Parameter Field
5. Problem to program a hex file less than 16 bytes
6. Unexpected Echo After Start Application Command
4
Version Number
1.0.0
1.0.2
1.0.3
1.0.4
Watchdog and Flash API Starting the Bootloader Execution
Start application with security set
When BLJB bit is active and SBV > 0x7F00 the Atmel bootlader is executed instead of a custom bootloader.
Workaround
Update to bootloader revision 1.0.2
When the bootloader receives the command ’Start Application’ (LJMP 0), the CAN is not stopped.
Workaround
The application must have in its setup function a reset of CAN macro.
When an application call ’__api_start_bootloader’ or’__api_start_isp’ routines while the watchdog is enabled, when the
watchdog overflow it will restart the application instead of the bootloader
Workaround
Set BLJB(=0) before calling the ‘__api_start_bootloader’ or ‘__api_start_isp’ if the watchdog is used.
When the Flash API ’__api_wr_code_page’ is called with the field ‘nb_data’ equals 0 then 255 data are written in Flash.
Workaround
Include a test on ‘nb_data’ before executing ‘__api_wr_code_page’ routine.
When we try to program a hex file with a size size less than 16 bytes, some errors appear depending of the start
address.
Workaround
Program with a range address higher than 16 bytes.
When the command start application (with reset) is received by the CAN bootloader; the bootloader answers with a
ramdom CAN frame before starting the application.
mov CANGCON, #00h
AT89C51CC03/C/U Errata Sheet
Errata List
1, 2, 3, 4, 5, 6, 7, 9
3, 8, 9
3, 8,10
3, 8
Date Code
0601 and above
4293G–CAN–06/05

Related parts for AT89C51CC03