Specifications of SAM3S1A

Flash (kbytes)
64 Kbytes
Pin Count
48
Max. Operating Frequency
64 MHz
Cpu
Cortex-M3
# Of Touch Channels
17
Hardware Qtouch Acquisition
No
Max I/o Pins
34
Ext Interrupts
34
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
2
Twi (i2c)
2
Uart
3
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
1000
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
16
Self Program Memory
YES
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
Figure 36-10. Method 1 (UPDM = 0)
6500C–ATARM–8-Feb-11
Method 1: Manual write of duty-cycle values and manual trigger of the update
UPDULOCK
CDTYUPD
CCNT0
CDTY
0x20
0x20
In this mode, the update of the period value, the duty-cycle values and the dead-time values
must be done by writing in their respective update registers with the CPU (respectively
PWM_CPRDUPDx, PWM_CDTYUPDx and PWM_DTUPDx).
To trigger the update, the user must use the bit UPDULOCK of the
Update Control Register”
PWM period) the synchronous channels:
After writing the UPDULOCK bit to 1, it is held at this value until the update occurs, then it is read
0.
Sequence for Method 1:
• If the bit UPDULOCK is set to 1, the update is done at the next PWM period of the
• If the UPDULOCK bit is not set to 1, the update is locked and cannot be performed.
1. Select the manual write of duty-cycle values and the manual update by setting the
2. Define the synchronous channels by the SYNCx bits in the PWM_SCM register.
3. Enable the synchronous channels by writing CHID0 in the PWM_ENA register.
4. If an update of the period value and/or the duty-cycle values and/or the dead-time val-
5. Set UPDULOCK to 1 in PWM_SCUC.
6. The update of the registers will occur at the beginning of the next PWM period. At this
synchronous channels.
UPDM field to 0 in the PWM_SCM register
ues is required, write registers that need to be updated (PWM_CPRDUPDx,
PWM_CDTYUPDx and PWM_DTUPDx).
moment the UPDULOCK bit is reset, go to
0x40
0x40
0x60
(PWM_SCUC) which allows to update synchronously (at the same
0x60
Step
4.) for new values.