SAM3S1A Atmel Corporation, SAM3S1A Datasheet - Page 982

no-image

SAM3S1A

Manufacturer Part Number
SAM3S1A
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3S1A

Flash (kbytes)
64 Kbytes
Pin Count
48
Max. Operating Frequency
64 MHz
Cpu
Cortex-M3
# Of Touch Channels
17
Hardware Qtouch Acquisition
No
Max I/o Pins
34
Ext Interrupts
34
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
2
Twi (i2c)
2
Uart
3
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
1000
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
16
Self Program Memory
YES
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
39.6.3
39.6.4
Figure 39-4. EOCx and DRDY Flag Behavior
982
982
(ADC_CHSR)
(ADC_SR)
(ADC_SR)
EOCx
DRDY
CHx
SAM3S
SAM3S
Conversion Resolution
Conversion Results
Write the ADC_CR
with START = 1
The ADC supports 10-bit or 12-bit resolutions. The 10-bit selection is performed by setting the
LOWRES bit in the ADC Mode Register (ADC_MR). By default, after a reset, the resolution is
the highest and the DATA field in the data registers is fully used. By setting the LOWRES bit, the
ADC switches to the lowest resolution and the conversion results can be read in the lowest sig-
nificant bits of the data registers. The two highest bits of the DATA field in the corresponding
ADC_CDR register and of the LDATA field in the ADC_LCDR register read 0.
Moreover, when a PDC channel is connected to the ADC, 12-bit or 10-bit resolution sets the
transfer request size to 16 bits.
When a conversion is completed, the resulting 12-bit digital value is stored in the Channel Data
Register (ADC_CDRx) of the current channel and in the ADC Last Converted Data Register
(ADC_LCDR). By setting the TAG option in the ADC_EMR, the ADC_LCDR presents the chan-
nel number associated to the last converted data in the CHNB field.
The channel EOC bit in the Status Register (ADC_SR) is set and the DRDY is set. In the case of
a connected PDC channel, DRDY rising triggers a data transfer request. In any case, either
EOC and DRDY can trigger an interrupt.
Reading one of the ADC_CDR registers clears the corresponding EOC bit. Reading ADC_LCDR
clears the DRDY bit and EOC bit corresponding to the last converted channel.
If the ADC_CDR is not read before further incoming data is converted, the corresponding Over-
run Error (OVREx) flag is set in the Overrun Status Register (ADC_OVER).
Likewise, new data converted when DRDY is high sets the GOVRE bit (General Overrun Error)
in ADC_SR.
The OVREx flag is automatically cleared when ADC_OVER is read, and GOVRE flag is auto-
matically cleared when ADC_SR is read.
Read the ADC_CDRx
Write the ADC_CR
with START = 1
Read the ADC_LCDR
6500C–ATARM–8-Feb-11
6500C–ATARM–8-Feb-11