SAM3S1B Atmel Corporation, SAM3S1B Datasheet - Page 344

no-image

SAM3S1B

Manufacturer Part Number
SAM3S1B
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3S1B

Flash (kbytes)
64 Kbytes
Pin Count
64
Max. Operating Frequency
64 MHz
Cpu
Cortex-M3
# Of Touch Channels
23
Hardware Qtouch Acquisition
No
Max I/o Pins
34
Ext Interrupts
34
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
3
Twi (i2c)
2
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
10
Adc Resolution (bits)
12
Adc Speed (ksps)
1000
Analog Comparators
1
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
12
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
16
Self Program Memory
YES
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
21.5.1
21.5.2
344
SAM3S
UART0 Serial Port
Xmodem Protocol
Communication is performed through the UART0 initialized to 115200 Baud, 8, n, 1.
The Send and Receive File commands use the Xmodem protocol to communicate. Any terminal
performing this protocol can be used to send the application file to the target. The size of the
binary file to send depends on the SRAM size embedded in the product. In all cases, the size of
the binary file must be lower than the SRAM size because the Xmodem protocol requires some
SRAM memory to work. See,
The Xmodem protocol supported is the 128-byte length block. This protocol uses a two-charac-
ter CRC-16 to guarantee detection of a maximum bit error.
Xmodem protocol with CRC is accurate provided both sender and receiver report successful
transmission. Each block of the transfer looks like:
<SOH><blk #><255-blk #><--128 data bytes--><checksum> in which:
Figure 21-2
Figure 21-2. Xmodem Transfer Example
• Get Version (V): Return the SAM-BA boot version
– Output: ‘>’
– Output: ‘>’
– <SOH> = 01 hex
– <blk #> = binary number, starts at 01, increments by 1, and wraps 0FFH to 00H (not
– <255-blk #> = 1’s complement of the blk#.
– <checksum> = 2 bytes CRC16
to 01)
shows a transmission using this protocol.
Host
Section 21.2 ”Hardware and Software Constraints”
SOH 01 FE Data[128] CRC CRC
SOH 02 FD Data[128] CRC CRC
SOH 03 FC Data[100] CRC CRC
ACK
ACK
ACK
EOT
ACK
C
Device