SAM3S4B Atmel Corporation, SAM3S4B Datasheet - Page 436

no-image

SAM3S4B

Manufacturer Part Number
SAM3S4B
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3S4B

Flash (kbytes)
256 Kbytes
Pin Count
64
Max. Operating Frequency
64 MHz
Cpu
Cortex-M3
# Of Touch Channels
23
Hardware Qtouch Acquisition
No
Max I/o Pins
79
Ext Interrupts
79
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
3
Twi (i2c)
2
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
10
Adc Resolution (bits)
12
Adc Speed (ksps)
1000
Analog Comparators
1
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
12
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
48
Self Program Memory
YES
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
26.13 Programming Sequence
436
SAM3S
1. Enabling the Main Oscillator:
2. Checking the Main Oscillator Frequency (Optional):
3. Setting PLL and Divider:
4. Selection of Master Clock and Processor Clock
In some situations the user may need an accurate measure of the main clock frequency.
This measure can be accomplished via the CKGR_MCFR register.
Once the MAINFRDY field is set in CKGR_MCFR register, the user may read the MAINF
field in CKGR_MCFR register. This provides the number of main clock cycles within sixteen
slow clock cycles.
All parameters needed to configure PLL and the divider are located in the CKGR_PLLxR
register.
The DIV field is used to control the divider itself. It must be set to 1 when PLL is used. By
default, DIV parameter is set to 0 which means that the divider is turned off.
The MUL field is the PLL multiplier factor. This parameter can be programmed between 0
and 2047. If MUL is set to 0, PLL will be turned off, otherwise the PLL output frequency is
PLL input frequency multiplied by (MUL + 1).
The PLLCOUNT field specifies the number of slow clock cycles before LOCK bit is set in the
PMC_SR register after CKGR_PLLR register has been written.
Once the PMC_PLL register has been written, the user must wait for the LOCK bit to be set
in the PMC_SR register. This can be done either by polling the status register or by waiting
the interrupt line to be raised if the associated interrupt to LOCK has been enabled in the
PMC_IER register. All parameters in CKGR_PLLR can be programmed in a single write
operation. If at some stage one of the following parameters, MUL, DIV is modified, LOCK bit
will go low to indicate that PLL is not ready yet. When PLL is locked, LOCK will be set again.
The user is constrained to wait for LOCK bit to be set before using the PLL output clock.
The Master Clock and the Processor Clock are configurable via the PMC_MCKR register.
The CSS field is used to select the Master Clock divider source. By default, the selected
clock source is main clock.
The PRES field is used to control the Master Clock prescaler. The user can choose between
different values (1, 2, 3, 4, 8, 16, 32, 64). Master Clock output is prescaler input divided by
PRES parameter. By default, PRES parameter is set to 1 which means that master clock is
equal to main clock.
Once the PMC_MCKR register has been written, the user must wait for the MCKRDY bit to
be set in the PMC_SR register. This can be done either by polling the status register or by
The main oscillator is enabled by setting the MOSCXTEN field in the CKGR_MOR reg-
ister. The user can define a start-up time. This can be achieved by writing a value in the
MOSCXTST field in the CKGR_MOR register. Once this register has been correctly
configured, the user must wait for MOSCXTS field in the PMC_SR register to be set.
This can be done either by polling the status register, or by waiting the interrupt line to
be raised if the associated interrupt to MOSCXTS has been enabled in the PMC_IER
register.
Start Up Time = 8 * MOSCXTST / SLCK = 56 Slow Clock Cycles.
So, the main oscillator will be enabled (MOSCXTS bit set) after 56 Slow Clock Cycles.
6500C–ATARM–8-Feb-11