SAM3S4B Atmel Corporation, SAM3S4B Datasheet - Page 980

no-image

SAM3S4B

Manufacturer Part Number
SAM3S4B
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3S4B

Flash (kbytes)
256 Kbytes
Pin Count
64
Max. Operating Frequency
64 MHz
Cpu
Cortex-M3
# Of Touch Channels
23
Hardware Qtouch Acquisition
No
Max I/o Pins
79
Ext Interrupts
79
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Full Speed
Usb Interface
Device
Spi
3
Twi (i2c)
2
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
10
Adc Resolution (bits)
12
Adc Speed (ksps)
1000
Analog Comparators
1
Resistive Touch Screen
No
Dac Channels
2
Dac Resolution (bits)
12
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
48
Self Program Memory
YES
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
39.5.6
39.5.7
39.5.8
39.5.9
39.6
39.6.1
980
980
Functional Description
SAM3S
SAM3S
Timer Triggers
PWM Event Line
Fault Output
Conversion Performances
Analog-to-digital Conversion
Table 39-3.
Timer Counters may or may not be used as hardware triggers depending on user requirements.
Thus, some or all of the timer counters may be unconnected.
PWM Event Lines may or may not be used as hardware triggers depending on user
requirements.
The ADC Controller has the FAULT output connected to the FAULT input of PWM. Please refer to
Section 39.6.12 ”Fault Output”
For performance and electrical characteristics of the ADC, see the product DC Characteristics
section.
The ADC uses the ADC Clock to perform conversions. Converting a single analog value to a 12-
bit digital data requires Tracking Clock cycles as defined in the field TRACKTIM of the
Mode Register” on page 993
same register. The ADC Clock frequency is selected in the PRESCAL field of the Mode Register
(ADC_MR). The tracking phase starts during the conversion of the previous channel. If the track-
ing time is longer than the conversion time, the tracking phase is extended to the end of the
previous conversion.
The ADC clock range is between MCK/2, if PRESCAL is 0, and MCK/512, if PRESCAL is set to
255 (0xFF). PRESCAL must be programmed in order to provide an ADC clock frequency
according to the parameters given in the product Electrical Characteristics section.
ADC
ADC
ADC
ADC
ADC
ADC
I/O Lines
and Transfer Clock cycles as defined in the field TRANSFER of the
and implementation of the PWM in the product.
AD10
AD11
AD12
AD13
AD14
AD9
PC13
PC15
PC12
PC29
PC30
PA22
6500C–ATARM–8-Feb-11
6500C–ATARM–8-Feb-11
X1
X1
X1
X1
X1
X1
“ADC

Related parts for SAM3S4B