AD7607 Analog Devices, AD7607 Datasheet - Page 28

no-image

AD7607

Manufacturer Part Number
AD7607
Description
8-Channel DAS with 14-Bit, Bipolar, Simultaneous Sampling ADC
Manufacturer
Analog Devices
Datasheet

Specifications of AD7607

Resolution (bits)
14bit
# Chan
8
Sample Rate
200kSPS
Interface
Par,Ser,SPI
Analog Input Type
SE-Bip
Ain Range
Bip 10V,Bip 5.0V
Adc Architecture
SAR
Pkg Type
QFP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7607BSTZ
Manufacturer:
ADI
Quantity:
32
Part Number:
AD7607BSTZ
Manufacturer:
ADI
Quantity:
250
Part Number:
AD7607BSTZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD7607BSTZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7607BSTZ-RL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
AD7607
If the OS[2:0] pins are set to select an oversampling ratio of 8,
for example, the next CONVST x rising edge takes the first sample
for each channel. The remaining seven samples for all channels
are taken with an internally generated sampling signal. As the
oversampling ratio is increased, the 3 dB frequency is reduced and
the allowed sampling frequency is also reduced (see Table 9). The
OS[2:0] pins should be configured to suit the filtering requirements
of the application.
The CONVST A and CONVST B pins must be tied/driven
together when oversampling is turned on. When the oversampling
function is turned on, the BUSY high time for the conversion
2000
1800
1600
1400
1200
1000
800
600
400
200
0
Figure 50. Histogram of Codes, Oversampling by 64
–2
–1
CODE
0
1
AV
V
T
10V RANGE
OS64
DRIVE
A
CC
= 25°C
= 5V
2
= 5V
Rev. B | Page 28 of 32
process extends. The actual BUSY high time depends on the over-
sampling rate that is selected: the higher the oversampling rate,
the longer the BUSY high or total conversion time (see Table 3).
Figure 51 shows that the conversion time extends as the over-
sampling rate is increased. To achieve the fastest throughput
rate possible when oversampling is turned on, the read can be
performed during the BUSY high time. The falling edge of BUSY
is used to update the output data registers with the new conversion
data; therefore, the reading of conversion data should not occur on
this edge.
CONVST A
CONVST B
DB[15:0]
Figure 51. No Oversampling, Oversampling by 4, and Oversampling by 8
DATA:
BUSY
AND
CS
RD
OS = 0 OS = 4 OS = 8
4µs
19µs
Using Read After Conversion
t
CONV
39µs
t
4
t
4
t
4
t
CYCLE
Data Sheet

Related parts for AD7607