TMPM382FSFG Toshiba, TMPM382FSFG Datasheet - Page 259

no-image

TMPM382FSFG

Manufacturer Part Number
TMPM382FSFG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMPM382FSFG

Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
64K
Rom Type
Flash
Ram (kbytes)
8K
Number Of Pins
64
Package
QFP(14x14)
Vcc
5V
Cpu Mhz
40
Ssp (ch) Spi
1
I2c/sio (ch)
1
Uart/sio (ch)
3
Usb
-
Can
-
Ethernet
-
External Bus Interface
N
Cs/wait Controller (ch)
-
Dma Controller
2
10-bit Da Converter
-
10-bit Ad Converter
-
12-bit Ad Converter
10
16-bit Timer / Counter
6
Motor / Igbt Control
Y
Real Time Clock
1
Watchdog Timer
Y
Osc Freq Detect
Y
Clock Gear
Y
Low-power Hold Function
-
Remote Control Interface
Y
Hardware Cec Controller
-
Comparators
-
Low-voltage Detector
Y
Etm Hardware Trace
2-bit
10.6.18 Noise canceller
10.6.19 Emergency stop function
10.6.19.1
10.6.19.2
10.6.19.3
10.6.19.4
GEMGn input is permitted. When a low level input is detected with GEMGn pin, MTOUT0n and
MTOUT1n waveform are initialized or become Hi-z state, and the GEMGn interrupt occurs specified
with MTnGEMGCR<IGEMGOC> setting.
stopping thus timer must be stopped in the interrupt routine.
“0” is read from IGEMGST, it indicates that the emergency output stop is enabled.
use a GEMG interrupt (INTMTENGn) for some processing, ensure that the interrupt is permitted
beforehand. When GEMGn pin is low, an attempt to cancel the emergency output stop state results
in an interrupt being generated again, with the emergency output stop state reestablished.
output stop state is released.
Digital noise canceller can be selected noise eliminating time with MTnIGIGR<IGNCSEL3:0> and
MTNIGEMGCR<IGEMGCNT3:0>.
When MTnIGEMGCR<IGEMGEN> is set to “1”, the emergency stop function is permitted, that is,
Note that this function is only prohibited the MTOUT0n and MTOUT1n outputs not the counter
When the emergency output stop feature activates, the MTnIGEMGST<IGEMGST> is set to “1”. If
A GEMG interrupt (INTMTENGn) occurs when an emergency output stop input is accepted. To
To cancel the emergency output stop state, perform the following steps:
A signal from external input pin (MTnIN, GEMGn) is eliminated noise by digital noise canceller.
1. Confirm GEMGn pin is high
2. Set MTnRUN<MTRUN> to “0”.
3. Confirm the timer operation stopped (MTnIGST<IGST>=0)
After confirming above steps, by setting to MTnIGEMGCR<IGEMGRS> to “1”, the emergency
Operating Description
Emergency Stop Monitoring
GEMG Interrupt
Cancelling the Emergency output stop state
TMPM380/M382 - 59 / 87 -
TMPM380/M382

Related parts for TMPM382FSFG