TMPM382FSFG Toshiba, TMPM382FSFG Datasheet - Page 329

no-image

TMPM382FSFG

Manufacturer Part Number
TMPM382FSFG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMPM382FSFG

Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
64K
Rom Type
Flash
Ram (kbytes)
8K
Number Of Pins
64
Package
QFP(14x14)
Vcc
5V
Cpu Mhz
40
Ssp (ch) Spi
1
I2c/sio (ch)
1
Uart/sio (ch)
3
Usb
-
Can
-
Ethernet
-
External Bus Interface
N
Cs/wait Controller (ch)
-
Dma Controller
2
10-bit Da Converter
-
10-bit Ad Converter
-
12-bit Ad Converter
10
16-bit Timer / Counter
6
Motor / Igbt Control
Y
Real Time Clock
1
Watchdog Timer
Y
Osc Freq Detect
Y
Clock Gear
Y
Low-power Hold Function
-
Remote Control Interface
Y
Hardware Cec Controller
-
Comparators
-
Low-voltage Detector
Y
Etm Hardware Trace
2-bit
12.1.1 Encoder Mode
12.1.2 Sensor Modes
12.1.2.1
12.1.2.2
signals from an incremental encoder.
A(U)/B(V) or A(U)/B(V)/Z(W) input signals from a Hall sensor.
In Encoder mode, the ENC provides high-speed position tracking, based on the A/B or A/B/Z input
In Sensor modes, the ENC provides low-speed position (zero-cross) tracking, based on either the
There are two operating modes: Event Count mode and Timer Count mode (which runs with fsys).
Event (rotation pulse) sensing: Programmable to generate an interrupt on each event.
Event counter: Programmable to generate an interrupt at a preset count (for positional
displacement calculation).
Direction discrimination
Up/down counting (dynamically selectable)
Programmable counter period
Event (rotation pulse) sensing: Programmable to generate an interrupt on each event.
Event counter: Programmable to generate an interrupt at a preset count (for positional
displacement calculation).
Direction discrimination
Event (rotation pulse) sensing: Programmable to generate an interrupt on each event.
Timer counting operation
Direction discrimination
Input capture functions
Event timeout error (timer compare): Programmable to generate an interrupt at a preset
count.
Revolution error: Error flag that indicates a change of the rotation direction
Event Count Mode
Event capture (event interval measurement): Programmable to generate an interrupt.
Software capture
Timer Count Mode
TMPM380/M382 - 3 / 23 -
TMPM380/M382

Related parts for TMPM382FSFG