ZY2110 Power-One, ZY2110 Datasheet

no-image

ZY2110

Manufacturer Part Number
ZY2110
Description
Zy2110 10a No-bus Pol
Manufacturer
Power-One
Datasheet
Applications
Benefits
Description
The ZY2110 is an intelligent, fully programmable step-down point-of-load DC-DC module integrating digital power
conversion and power management. The ZY2110 completely eliminates the need for external components for
sequencing, tracking, protection, monitoring, and reporting.
programmable by pin strapping and an external resistor and can be changed by the user at any time during
product development and service without a need for a communication bus.
Reference Documents
No-Bus
Z-One
Z-One
ZD-02013 REV. B1
Low voltage, high density systems with
Intermediate Bus Architectures (IBA)
Point-of-load regulators for high performance DSP,
FPGA, ASIC, and microprocessor applications
Industrial computing, servers, and storage
Broadband, networking, optical, and wireless
communications systems
Active memory bus terminators
Integrates digital power conversion with intelligent
power management
Eliminates the need for external power
management components and communication bus
Completely programmable via pin strapping and
one external resistor
One part that covers all applications
Reduces board space, system cost and
complexity, and time to market
®
®
TM
POL Converters. Eutectic Solder Process Application Note
POL Converters. Lead-Free Process Application Note
POL Converters. Application Note
www.power-one.com
Features
8V to 14V Input
ZY2110 10A No-Bus POL Data Sheet
RoHS lead free and lead-solder-exempt products are
available
Wide input voltage range: 8V–14V
High continuous output current: 10A
Wide programmable output voltage range: 0.5V–5.5V
Output voltage margining
Overcurrent and overtemperature protections
Overvoltage and undervoltage protections, and Power
Good signal tracking the output voltage setpoint
Tracking during turn-on and turn-off with guaranteed
slew rates
Sequenced and cascaded modes of operation
Single-wire line for frequency synchronization
between multiple POLs
Programmable feedback loop compensation
Enable control
Flexible fault management and propagation
Start-up into the load pre-biased up to 100%
Current sink capability
Industry standard size through-hole single-in-line
package: 1.2”x0.26”
Low height of 0.84”
Wide operating temperature range: 0 to 70ºC
UL60950 recognized, CSA C22.2 No. 60950-00
certified, and TUV EN60950-1:2001 certified
(pending)
Member of the
Performance parameters of the ZY2110 are
0.5V to 5.5V Output
Page 1 of 13
Family

Related parts for ZY2110

ZY2110 Summary of contents

Page 1

... Reduces board space, system cost and complexity, and time to market Description The ZY2110 is an intelligent, fully programmable step-down point-of-load DC-DC module integrating digital power conversion and power management. The ZY2110 completely eliminates the need for external components for sequencing, tracking, protection, monitoring, and reporting. ...

Page 2

... Mercury (Hg), Polybrominated biphenyls (PBB), Polybrominated diphenylethers (PBDE), and Lead (Pb) used anywhere except in solder. 2 Packaging option is used only for ordering and not included in the part number printed on the POL converter label. Example: ZY2110G-R3: A 48-piece tray of RoHS compliant POL converters. Each POL converter is labeled ZY2110G. 2. Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long- term reliability, and cause permanent damage to the POL converter ...

Page 3

... Temperature Coefficient Switching Frequency 1 At the negative output current (bus terminator mode) efficiency of the ZY2110 degrades resulting in increased internal power dissipation. Therefore maximum allowable negative current under specific conditions is 20% lower than the current determined from the derating curves shown in paragraph 5.5 2 Digital PWM has an inherent quantization uncertainty of ± ...

Page 4

... Follows the output voltage setpoint From instant when threshold is exceeded until Delay Threshold Accuracy ___________________ 1 Minimum OVP threshold is 1.0V ZD-02013 REV. B1 ZY2110 10A No-Bus POL Data Sheet 8V to 14V Input Conditions/Description Output Overcurrent Protection Output Overvoltage Protection Measured at V =2.5V O.SET Output Undervoltage Protection Measured ...

Page 5

... Turn-On Delay From EN pin changing state to V Turn-Off Delay CCA pin is open combination of ceramic + tantalum CCA pin is connected to GND Recommended C ZD-02013 REV. B1 ZY2110 10A No-Bus POL Data Sheet 8V to 14V Input Conditions/Description Tracking Proportional to SYNC frequency Proportional to SYNC frequency Enable (EN pin) OUT ...

Page 6

... Iup_OK Pull-up current source V(OK)=0 ViL_x ViH_x Vhyst_x Hysteresis of input Schmitt trigger IoL_x LOW level sink current at 0.5V ZD-02013 REV. B1 ZY2110 10A No-Bus POL Data Sheet 8V to 14V Input Conditions/Description Internal supply voltage 3.15 SYNC Line LOW level input voltage 0.75 x HIGH level input voltage VDD 0 ...

Page 7

... Figure 1. Efficiency vs. Load. Vin=9. Vo=5V Vo=3.3V 65 Vo=1.8V Vo=1. Output Current, A Figure 2. Efficiency vs. Load. Vin=12V ZD-02013 REV. B1 ZY2110 10A No-Bus POL Data Sheet 8V to 14V Input Vo=2. Figure 3. Efficiency vs. Output Voltage, Iout=10A Vo=2.5V 75 ...

Page 8

... Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 – V3 5.3 Turn-Off Characteristics Figure 6. Tracking Turn-Off Vin=12V, Ch1 – V1, Ch2 – V2, Ch3 – V3 ZD-02013 REV. B1 ZY2110 10A No-Bus POL Data Sheet 8V to 14V Input 5.4 Transient Response The pictures below show the deviation of the output voltage in response to the 50%-100%-50% step load at 2.5A/µ ...

Page 9

... LFM (0.5 m/s) 200 LFM (1 m/s) 300 LFM (1.5 m/s) 4 400 LFM (2 m/s) 500 LFM (2.5 m/ Figure 11. Thermal Derating Curves. Vin=12V, Vout=5V ZD-02013 REV. B1 ZY2110 10A No-Bus POL Data Sheet 8V to 14V Input Figure 10. Vin=12V, Vout=1V. CCA Ambient Temperature, C www.power-one.com 0.5V to 5.5V Output • Page ...

Page 10

... POL1 is configured as a master (IM pin is grounded) and all other POL converters are synchronized to the switching frequency of POL1. All converters are controlled by the common ENABLE signal. Turn-on and turn-off processes of the system are illustrated by pictures in Figure 5 and Figure 6. ZD-02013 REV. B1 ZY2110 10A No-Bus POL Data Sheet 8V to 14V Input OK VIN 22uF 4 ...

Page 11

... PG, Power Good The open drain input/output with the internal pull-up resistor. The pin is pulled low by the POL converter, ZD-02013 REV. B1 ZY2110 10A No-Bus POL Data Sheet 8V to 14V Input Pin Description Connect to OK pin of other Z- POLs. Leave Fault Status Frequency Synchronization ...

Page 12

... R DOWN TRIM − 100 ⎝ ZD-02013 REV. B1 ZY2110 10A No-Bus POL Data Sheet 8V to 14V Input where R TRIM ∆V% is the absolute value of desired margining expressed in percents of the nominal output voltage. During normal operation the resistors are removed from the circuit by the switches. ...

Page 13

... Power-One, Inc. 2. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. ZD-02013 REV. B1 ZY2110 10A No-Bus POL Data Sheet 8V to 14V Input All Dimensions are in mm XX.X: ±0.1 XX.XX: ± ...