3.7 Command Description for Operating Mode
The Operating Mode is a mode of the reader for using a set of standard commands as described in
the following.
In this mode the BCC is computed by EXOR-operation of all block data bytes including Block
Length.
The command KeyInitMode is used to enter the KeyInit Mode (mode of the read/write device for
using personalization commands), and a different set of commands becomes available.
3.7.1 GetSnr
This command provides the serial number of a HITAG 1 transponder in Standard Protocol Mode.
For further information on the Standard Protocol Mode see chapter „Transponders“.
C-Function: void proloc_GetSnr (DWORD_T *snr, BYTE_T *more);
Header-File: PROLIB6.H
Serial protocol:
HOST - READ/WRITE DEVICE
READ/WRITE DEVICE - HOST
n = 0 if an error occurred (error code in Status).
n = 5 if data were read from a transponder (Status = 0).
more: Proximity Reader:
Status:
Htswp.doc/HS
0x02
n+2
Long Range Reader: more equal to one indicates that there is at least one additional
'G'
Status
-1 ...
-3 ...
0 ... no error
0x45
SERIAL ERROR
NOTAG
7
SNR-LSB
more is always 0.
transponder in the reading area of the read/write device.
0
------
------
Page 16 (104)
Rev. 1.0
31
SNR-MSB
24
more
BCC
98-02-10