HT-CM400 NXP Semiconductors, HT-CM400 Datasheet - Page 31

no-image

HT-CM400

Manufacturer Part Number
HT-CM400
Description
Ht Cm400; Ht Rm440 Family; Ht Rm800 Family Interface Protocol Reader - Host
Manufacturer
NXP Semiconductors
Datasheet
98-02-10
3.7.16 ReadPageInv_LT
Reads a bit-inverted page (4 bytes) of a selected HITAG 2 transponder.
If no transponder is selected, a NOTAG message will be generated.
This command should be used together with ReadPage_LT to compare plain data with the bit-
inverted data to gain maximum data reliability.
C-Function: void proloc_ReadPageInv_LT (BYTE_T pagenr, char *data);
Header-File: PROLBLT6.H
Serial protocol:
HOST - READ/WRITE DEVICE
pagenr:
READ/WRITE DEVICE - HOST
n = 0 if an error occurred (error code in Status).
n = 4 if data were read from a transponder (Status = 0).
Status:
0x03
n+2
Status
0x83
page number
-1 ...
-3 ...
0 ... no error
SERIAL ERROR
NOTAG
pagenr
data[0]
BCC
.......
Page 31 (104)
Rev. 1.0
data[3]
BCC
Communication Reader-Host
Htswp.doc/HS

Related parts for HT-CM400