ACS60US36 XP Power, ACS60US36 Datasheet

no-image

ACS60US36

Manufacturer Part Number
ACS60US36
Description
Ac-dc Power Supplies
Manufacturer
XP Power
Datasheet
40-60 Watts
ACS Series
Specification
Input
Output
1
Input Voltage
Input Frequency
Input Current
Inrush Current
Earthing
Output Voltage
Output Voltage Trim
Hold Up Time
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage Protection • Typically 130% of max output
Overcurrrent Protection • 120% typical
• 90-264 VAC (110-370 VDC)
• 47-63 Hz
• ACS40: 0.45 A rms at 230 VAC
• Cold start at 25 ºC: 25 A at 115 VAC,
• Class I
• See table
• ±5%
• 8 ms typical at full load
• 0.5%max at full load
• 1.0% max at 10% load to full load
• 1% max pk-pk, 20MHz BW
ACS60: 0.60 A rms at 230 VAC
50 A at 230 VAC
General
Environmental
EMC & Safety
Efficiency
Isolation
Switching Frequency
MTBF
Operating Temperature • 0 ºC to +70 ºC, derate from full load at
Storage Temperature
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Safety Approvals
Low Cost
Small Size
Universal Input
Rugged Design
High MTBF
International Safety Approvals
Covered Versions Available
• See tables
• 3000 VAC Input to Output
• 50-70 kHz
• 230 kHrs per MIL-HDBK-217F
• -40 ºC to +85 ºC
• FCC20780 Level B, CISPR22 (EN55022),
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 10 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
• EN61000-4-5, level 3 Perf Criteria A
• EN61000-4-6, 10 V Perf Criteria y
• EN60950, UL1950, CSA22.2 No. 234
1500 VAC Input to Ground
500 VAC Output to Ground
+50 ºC to half load at +60 ºC.
Reduce both temperatures by 10 ºC when
cover is fitted
level B conducted
xppower.com