cs1w-ad Omron Corporation, cs1w-ad Datasheet

no-image

cs1w-ad

Manufacturer Part Number
cs1w-ad
Description
Cs Series Analog I/o Unit
Manufacturer
Omron Corporation
Datasheet
For Various Analog I/Os
Features
Analog Input Unit:
Analog Output Unit:
Analog I/O Unit:
System Configuration
CS-series PLCs
Note: The above diagram is an installation example for the CS1W-AD081-V1 Analog Input Unit and CS1W-DA08V Analog Output Unit.
• Analog Input Units for converting analog input
• Analog Output Units for converting binary data
• Holds a maximum of 16 analog input signals in 1 unit.
• Reduces wiring using MIL connector (CS1W-AD161)
• Connector-Terminal Block Conversion Unit and Connecting Cable available for CS1W-AD161
• With functions including line disconnection detection, peak value holding, as well as mean value processing
• Scaling function (CS1W-AD161 only)
• Outputs a maximum of 8 analog output signals in 1 unit.
• Output hold function
• Has both analog input and output signals
• Ratio conversion function stores the results of positive and negative gradient analog inputs calculated for ratio and bias as analog output values
• Hold a maximum of 4 analog input signals and outputs 4 analog output signals in 1 unit
Temperature
Pressure
Speed
Flow rate
Voltage
Current
Power
Power factor
CS Series Analog I/O Unit
CS1W-AD/DA/MAD
signals into binary data
into analog output signals
Analog Input functions - Peak value holding, mean value processing and line disconnection detection
Analog Output functions - Output hold function
Analog Input Unit
Sensor
Sensor
Transducer
AD081
6
6
8
8
Preamp
5
5
7
7
V
V
V
DA08V
V
V
V
V
V
4
6
6
8
8
V
V
V
V3
V5
V5
V7
V7
3
Analog Output
Unit
Variable speed
controller
Regulator
Servo-
controller
Chart
recorder
CPU Unit
(Temperature control)
(Position control)
(Speed control)
CS1W-MAD44
CS1W-DA08V
CSM_CS1W-AD_DA_MAD_DS_E_1_1
CS1W-AD081-V1
1

Related parts for cs1w-ad

cs1w-ad Summary of contents

Page 1

... Preamp Speed Flow rate Voltage Current Transducer Power Power factor Sensor Note: The above diagram is an installation example for the CS1W-AD081-V1 Analog Input Unit and CS1W-DA08V Analog Output Unit. CS1W-MAD44 CS1W-DA08V CPU Unit Regulator (Temperature control) Servo- controller (Position control) Variable speed ...

Page 2

... CS1W-AD/DA/MAD Current consumption No. of (A) Unit Model Standards numbers allocated 5V 26V CS1W-AD041-V1 1 0.12 0.09 UC1 CS1W-AD081-V1 0.12 0.09 2 UC1, CS1W-AD161 0.15 0.06 CE − − XW2D-34G6 − − XW2Z-200C Current No. of consumption Unit Model Standards (A) numbers allocated 5V 26V UC1, CS1W-DA041 0.13 0. CS1W-DA08V ...

Page 3

... Individual Specifications Analog Input Units CS1W-AD041-V1/AD081-V1/AD161 Specifications Item Applicable PLC model CS series Unit type CS1 Special I/O Unit Between I/O and PLC signals: Photocoupler Isolation *1 (No isolation between individual I/O signals.) External terminals 21-point detachable terminal block (M3 screws) Affect on CPU Unit cycle time ...

Page 4

... Input signal ranges can be set for each input. *6. Voltage input or current input is selected for the CS1W-AD041-V1 and CS1W-AD081-V1 by using the voltage/current switch at the back of the terminal block. Voltage input or current input is selected for the CS1W-AD161 by wiring the connector terminals. Voltage/current selection for input ranges can be set in DM word m+52 ...

Page 5

... With Terminal Block AD081 Unit number setting switch External terminal block mounting Voltage/ screws (black M3) Current switch External terminal block (M3) Side Terminal block CS1W-AD/DA/MAD With Terminal Block Removed AD081 Voltage/ Current switch ...

Page 6

... Alarm has occurred (such as disconnection detection) or initial settings are incorrect. Operating normally. Operating in offset/gain adjustment mode. Other than the above. Error has occurred during data exchange with the CPU Unit. Operating normally. CS1W-AD/DA/MAD · m. Mode Switch (two poles) PC21 bus connector 6 ...

Page 7

... Input circuit and conversion 15 kΩ circuit AG (common to all inputs) 15 kΩ Input circuit and conversion circuit 15 kΩ AG (common to all inputs) MPU A/D converter EEPROM Regulator Insulation-type +26V DC-to-DC converter CS1W-AD/DA/MAD Externally connected Multi- terminal plexer and amplifier INPUT +15V +5V −15V 7 ...

Page 8

... The AG terminals (A8, B8) are connected to the 0-V analog circuit in the Unit. Connecting shielded input lines can improve noise resistance not make any connections to the N.C. terminals. og circuit in the Unit. Connecting shielded in- put lines can improve noise resistance. CS1W-AD/DA/MAD CS1W-AD081-V1 A1 Input 1+ Input Input 1− ...

Page 9

... Analog Output Unit to CPU Unit Alarm flags Output signal conversion enable/disable, CPU Unit to Analog Output Unit output signal range setting Output status for output hold CS1W-AD/DA/MAD CS1W-DA08C 130 mA max VDC, 250 mA max VDC 600 Ω (current output) *8 ...

Page 10

... Analog output 4 Same as above. Analog output 5 Same as above. Analog output 6 Same as above. Analog output 7 Analog output 8 Same as above. Note: There are only four analog outputs for the CS1W-DA041. Analog Output Unit D/A CS1W-AD/DA/MAD CPU Unit Special I/O Unit Area Analog output 1 set value 10 ...

Page 11

... CS1W-DA08V DA08V Unit number setting switch External terminal block (M3) Terminal block CS1W-AD/DA/MAD CS1W-DA08C DA08V Side 11 ...

Page 12

... Alarm has occurred (such as disconnection detection) or initial settings are incorrect. Operating normally. Operating in offset/gain adjustment mode. Other than the above. Error has occurred during data exchange with the CPU Unit. Operating normally. Voltage output (+) Voltage output (−) Current output (+) Current output (−) CS1W-AD/DA/MAD 12 ...

Page 13

... MPU D/A converter EEPROM Regulator Insulation-type +26 V DC-to-DC converter CS1W-DA041 N.C. Output voltage 2+ Output 2− Output current 2+ N.C. N.C. Output voltage 4− Output 4− Output current 4+ N.C. CS1W-AD/DA/MAD OUTPUT Multi- Externally plexer connected and terminal amplifier +18 V/+ − N. Output voltage Output 1− ...

Page 14

... Buffer number 16, 32, 64 Stores the maximum conversion value while the Peak Value Hold Bit is ON. Detects the disconnection and turns ON the Disconnection Detection Flag. CS1W-AD/DA/MAD Analog output Peak value hold Conversion Enable Bit Analog input ...

Page 15

... Stores the results of positive and negative gradient analog inputs calculated for ratio and bias as analog output values. Positive gradient: Analog output = A × Analog input + 99.99 8,000 to 7FFF Hex) Negative gradient: Analog output = F − A × Analog input + 99.99 8,000 to 7FFF Hex output range max. value) CS1W-AD/DA/MAD 15 ...

Page 16

... Mean value Peak value processing hold function enabled enabled Ratio conversion disabled Ratio con- Ratio conversion version enabled D/A Ratio conversion disabled CS1W-AD/DA/MAD CPU Unit Special I/O Unit Area I/O refresh Analog input 1 conversion value Analog output 1 conversion value 16 ...

Page 17

... External Interface CS1W-MAD44 With Terminal Block External terminal block mounting screws (black M3) Back Operation mode switch Backplane connector Front With Terminal Block Removed Unit number setting switch External terminal block (M3) Side Terminal block CS1W-AD/DA/MAD Voltage/Current switch 17 ...

Page 18

... Operating normally. Operating in offset/gain adjustment mode. Other than the above. Error has occurred during data exchange with the CPU Unit. Operating normally. 15 kΩ Input circuit and conversion 15 kΩ circuit AG (common to all inputs) Voltage output (+) Voltage output (−) CS1W-AD/DA/MAD 18 ...

Page 19

... The AG terminal (A8, B8) is connected to the 0-V analog circuit in the Unit. Connecting shielded input lines can improve noise resistance. 4. The N.C. terminals (A5, A11, B5) are not connected to internal circuitry. Multi- D/A MPU plexer converter and amplifier Multi- A/D plexer and converter amplifier EEPROM Regulator Insulation-type +26 V DC-to-DC converter CS1W-AD/DA/MAD OUTPUT Externally connected terminal INPUT + − ...

Page 20

... Dimensions CS-series Units: CS1W-AD041-V1/081-V1, CS1W-DA08V/08C/041, CS1W-MAD44 130 35 CS1W-AD161 34.5 130 CS-series Unit Terminal Block Dimensions Terminal size: M3 8.23 7.62 7.62 6.4 92.66±0.1 4.5 8.4 17.8 101 126 118.03 100.5 CS1W-AD/DA/MAD (Unit: mm) 20 ...

Page 21

... About this Manual Name SYSMAC CS/CJ-series Analog I/O Units Operation Manual CS1W-AD041-V1/AD081-V1/AD161, CS1W-DA041/DA08V/DA08C, CS1W-MAD44, CJ1W-AD041-V1/AD081-V1, CJ1W-DA021/DA041/DA08V/DA08C, CJ1W-MAD42 SYSMAC CS-series Programmable Controllers Operation Manual CS1G/H-CPU@@-EV1, CS1G/H-CPU@@H SYSMAC CS Series CS1D Duplex System Operation Manual CS1D-CPU@@H CPU Units, CS1D-CPU@@S CPU Units, ...

Page 22

... OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ Read and Understand This Catalog Warranty and Limitations of Liability Application Considerations Disclaimers In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2008 All Right Reserved. 2008.11 ...