m58bw32f STMicroelectronics, m58bw32f Datasheet - Page 36

no-image

m58bw32f

Manufacturer Part Number
m58bw32f
Description
16 Or 32 Mbit X32, Boot Block, Burst 3.3v Supply Flash Memories
Manufacturer
STMicroelectronics
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
m58bw32fB4T3F
Manufacturer:
INTEL
Quantity:
1 000
Part Number:
m58bw32fB4T3F
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
m58bw32fB4T3T
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
m58bw32fB4ZA3
Manufacturer:
NUMONYX
Quantity:
11 200
Part Number:
m58bw32fB4ZA3
Manufacturer:
ST
0
Part Number:
m58bw32fB4ZA3
Manufacturer:
ST
Quantity:
20 000
Part Number:
m58bw32fB4ZA3F
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
m58bw32fB4ZA3T
Manufacturer:
MAXIM
Quantity:
3 586
Part Number:
m58bw32fB4ZA3T
Manufacturer:
Micron Technology Inc
Quantity:
10 000
Part Number:
m58bw32fB5T3F
Manufacturer:
SUMIDA
Quantity:
4 000
Part Number:
m58bw32fB5T3T
Manufacturer:
MURATA
Quantity:
3 000
Command interface
4.9
36/87
Write to Buffer and Program command
The Write to Buffer and Program command makes use of the device’s double word (32 bit)
Write Buffer to speed up programming.
Up to eight double words can be loaded into the Write Buffer and programmed into the
memory.
Four successive steps are required to issue the command.
1.
2.
3.
4.
If any address is outside the block boundaries or if the correct sequence is not followed,
Status Register bits 4 and 5 are set to ‘1’ and the operation will abort without affecting the
data in the memory array. A protected block must be unprotected using the Blocks Unprotect
command.
During a Write to Buffer and Program operation the memory will only accept the Read
Status Register and the Program/Erase Suspend commands. All other commands are
ignored. If PEN is at V
operation aborts and the Status Register PEN bit (bit 3) is set to '1'.
The Status Register should be cleared before re-issuing the command.
One Bus Write operation is required to set up the Write to Buffer and Program
command. Any Bus Read operations will start to output the Status Register after the
1st cycle.
Use one Bus Write operation to write the selected memory block address (any address
in the block where the values will be programmed can be used) along with the value N
on the Data inputs/outputs, where N+1 is the number of words to be programmed. The
maximum value of N+1 is 8 words.
Use N+1 Bus Write operations to load the address and data for each word into the write
buffer. The address must be between Start address and Start address plus N, where
Start address is the first word address.
Finally, use one Bus Write operation to issue the final cycle to confirm the command
and start the Program operation.
IH
, the operation will be performed. If PEN is lower than V
M58BW16F, M58BW32F
IH
the

Related parts for m58bw32f