lm50b-mdc National Semiconductor Corporation, lm50b-mdc Datasheet
lm50b-mdc
Related parts for lm50b-mdc
lm50b-mdc Summary of contents
Page 1
... Operates from 4.5V to 10V n Less than 130 µA current drain n Low self-heating, less than 0.2˚C in still air n Nonlinearity less than 0.8˚C over temp n UL Recognized Component Order Number LM50BIM3 LM50CIM3 LM50BIM3X LM50CIM3X DS012030 February 2006 Device Supplied As Top Mark T5B 1000 Units on Tape ...
Page 2
Typical Application FIGURE 1. Full-Range Centigrade Temperature Sensor (−40˚C to +125˚C) www.national.com 01203003 2 ...
Page 3
... Soldering process must comply with National Semiconduc- 2000V tor’s Reflow Temperature Profile specifications. Refer to 250V www.national.com/packaging. (Note and LOAD = all other limits MIN MAX A Conditions LM50B Typical (Note 5) = +25˚ MAX = T +3.0, −3.5 MIN +10.3 2000 ≤ +10V S ≤ +10V S ≤ +10V S +1.0 ± ...
Page 4
Typical Performance Characteristics circuit board as shown in Figure 2. Thermal Resistance Junction to Air Thermal Response in Still Air with Heat Sink (Figure 2) Start-Up Voltage vs Temperature www.national.com To generate these curves the LM50 was mounted to a ...
Page 5
Typical Performance Characteristics circuit board as shown in Figure 2. (Continued) Quiescent Current vs Temperature (Figure 1) Noise Voltage Start-Up Response To generate these curves the LM50 was mounted to a printed Accuracy vs Temperature 01203027 01203029 01203031 5 01203028 ...
Page 6
Printed Circuit Board FIGURE 2. Printed Circuit Board Used for Heat Sink to Generate All Curves. ⁄ " Square Printed Circuit Board 1 2 with 2 oz. Foil or Similar 1.0 Mounting The LM50 can be applied easily in the ...
Page 7
Capacitive Loads (Continued) *R2 ≈ 2k with a typical 1300 ppm/˚C drift. 3.0 Typical Applications FIGURE 6. Centigrade Thermostat/Fan Controller FIGURE 7. Temperature To Digital Converter (Serial Output) (+125˚C Full Scale) FIGURE 5. Block Diagram 7 01203017 01203011 01203013 ...
Page 8
Typical Applications FIGURE 8. Temperature To Digital Converter (Parallel TRI-STATE Standard Data Bus to µP Interface) (125˚C Full Scale) FIGURE 9. LM50 With Voltage-To-Frequency Converter And Isolated Output www.national.com (Continued) (−40˚C to +125˚C; 100 Hz to 1750 Hz) 8 ...
Page 9
... Deutsch Tel: +49 (0) 69 9508 6208 English www.national.com Français Tel: +33 ( 8790 Order Number LM50BIM3, or LM50CIM3 NS Package Number mf03a 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system affect its safety or effectiveness ...