attiny13-20ss ATMEL Corporation, attiny13-20ss Datasheet - Page 22

no-image

attiny13-20ss

Manufacturer Part Number
attiny13-20ss
Description
8-bit Microcontroller With 1k Bytes In-system Programmable Flash - Atmel Corporation
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
attiny13-20ssI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
attiny13-20ssJ
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
attiny13-20ssU
Quantity:
2 180
Company:
Part Number:
attiny13-20ssU
Quantity:
100
Company:
Part Number:
attiny13-20ssU
Quantity:
739
Part Number:
attiny13-20ssU-SL383
Manufacturer:
ATMEL
Quantity:
4 132
Clock Sources
Default Clock Source
22
ATtiny13
The device has the following clock source options, selectable by Flash Fuse bits as
shown below. The clock from the selected source is input to the AVR clock generator,
and routed to the appropriate modules.
Table 2. Device Clocking Options Select
Note:
The various choices for each clocking option is given in the following sections. When the
CPU wakes up from Power-down or Power-save, the selected clock source is used to
time the start-up, ensuring stable Oscillator operation before instruction execution starts.
When the CPU starts from reset, there is an additional delay allowing the power to reach
a stable level before commencing normal operation. The Watchdog Oscillator is used
for timing this real-time part of the start-up time. The number of WDT Oscillator cycles
used for each time-out is shown in Table 3.
Table 3. Number of Watchdog Oscillator Cycles
The device is shipped with CKSEL = “10”, SUT = “10”, and CKDIV8 programmed. The
default clock source setting is therefore the Internal RC Oscillator running at 9.6 MHz
with longest start-up time and an initial system clock prescaling of 8. This default setting
ensures that all users can make their desired clock source setting using an In-System or
High-voltage Programmer.
Device Clocking Option
Calibrated Internal RC Oscillator
External Clock
128 kHz Internal Oscillator
1. For all fuses “1” means unprogrammed while “0” means programmed.
Typ Time-out
64 ms
4 ms
(1)
Number of Cycles
8K (8,192)
512
CKSEL1..0
01, 10
2535G–AVR–01/07
00
11