attiny13-20ss ATMEL Corporation, attiny13-20ss Datasheet - Page 86

no-image

attiny13-20ss

Manufacturer Part Number
attiny13-20ss
Description
8-bit Microcontroller With 1k Bytes In-system Programmable Flash - Atmel Corporation
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
attiny13-20ssI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
attiny13-20ssJ
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
attiny13-20ssU
Quantity:
2 180
Company:
Part Number:
attiny13-20ssU
Quantity:
100
Company:
Part Number:
attiny13-20ssU
Quantity:
739
Part Number:
attiny13-20ssU-SL383
Manufacturer:
ATMEL
Quantity:
4 132
Changing Channel or
Reference Selection
ADC Input Channels
86
ATtiny13
The MUXn and REFS1:0 bits in the ADMUX Register are single buffered through a tem-
porary register to which the CPU has random access. This ensures that the channels
and reference selection only takes place at a safe point during the conversion. The
channel and reference selection is continuously updated until a conversion is started.
Once the conversion starts, the channel and reference selection is locked to ensure a
sufficient sampling time for the ADC. Continuous updating resumes in the last ADC
clock cycle before the conversion completes (ADIF in ADCSRA is set). Note that the
conversion starts on the following rising ADC clock edge after ADSC is written. The user
is thus advised not to write new channel or reference selection values to ADMUX until
one ADC clock cycle after ADSC is written.
If Auto Triggering is used, the exact time of the triggering event can be indeterministic.
Special care must be taken when updating the ADMUX Register, in order to control
which conversion will be affected by the new settings.
If both ADATE and ADEN is written to one, an interrupt event can occur at any time. If
the ADMUX Register is changed in this period, the user cannot tell if the next conversion
is based on the old or the new settings. ADMUX can be safely updated in the following
ways:
When updating ADMUX in one of these conditions, the new settings will affect the next
ADC conversion.
When changing channel selections, the user should observe the following guidelines to
ensure that the correct channel is selected:
In Single Conversion mode, always select the channel before starting the conversion.
The channel selection may be changed one ADC clock cycle after writing one to ADSC.
However, the simplest method is to wait for the conversion to complete before changing
the channel selection.
In Free Running mode, always select the channel before starting the first conversion.
The channel selection may be changed one ADC clock cycle after writing one to ADSC.
However, the simplest method is to wait for the first conversion to complete, and then
change the channel selection. Since the next conversion has already started automati-
cally, the next result will reflect the previous channel selection. Subsequent conversions
will reflect the new channel selection.
1. When ADATE or ADEN is cleared.
2. During conversion, minimum one ADC clock cycle after the trigger event.
3. After a conversion, before the Interrupt Flag used as trigger source is
cleared.
2535G–AVR–01/07

Related parts for attiny13-20ss