ADuM6200/ADuM6201/ADuM6202
REGULATORY INFORMATION
The ADuM6200/ADuM6201/ADuM6202 are approved by the organizations listed in Table 15. Refer to Table 20 and the Insulation Lifetime
section for more information about the recommended maximum working voltages for specific cross-insulation waveforms and insulation
levels.
Table 15.
UL (Pending)
Recognized under UL 1577 component
recognition program
Single protection, 5000 V rms isolation
voltage
File E214100
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 16.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Distance (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Material Group
In accordance with UL 1577, each ADuM6200/ADuM6201/ADuM6202 is proof-tested by applying an insulation test voltage ≥ 6000 V rms for 1 sec (current leakage
detection limit = 15 μA).
In accordance with IEC 60747-5-2 (VDE 0884 Part 2):2003-01, each ADuM6200/ADuM6201/ADuM6202 is proof-tested by applying an insulation test voltage ≥ 1590 V peak
for 1 sec (partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates IEC 60747-5-2 (VDE 0884 Part 2):2003-01 approval.
1
CSA
Approved under CSA Component Acceptance Notice #5A
Reinforced insulation per CSA 60950-1-03 and IEC 60950-1,
380 V rms (537 V peak) maximum working voltage
Reinforced insulation per IEC 60601-1, 125 V rms (176 V peak)
maximum working voltage
Basic insulation per CSA 60950-1-03 and IEC 60950-1,
600 V rms (848 V peak) maximum working voltage
File 205078
Symbol
L(I01)
L(I02)
CTI
Rev. 0 | Page 8 of 24
Value
5000
8.0
7.6
0.017 min
>175
IIIa
Unit
V rms
mm
mm
mm
V
Test Conditions/Comments
1-minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Distance through insulation
DIN IEC 112/VDE 0303, Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
VDE (Pending)
Certified according to IEC 60747-5-2
(VDE 0884 Part 2):2003-01
Basic insulation, 846 V peak
File 2471900-4880-0001