micro-bdcbb Lineage Power, micro-bdcbb Datasheet

no-image

micro-bdcbb

Manufacturer Part Number
micro-bdcbb
Description
-48v Dc Battery Distribution Circuit Breaker Bay
Manufacturer
Lineage Power
Datasheet
Micro-BDCBB
-48V DC Battery Distribution Circuit Breaker Bay
01/10
Overview
The Lineage Power Micro-BDCBB serves
as a secondary power distribution center
for -48 V DC power delivered from a
battery plant to the load equipment. The
configuration is versatile with fuse or circuit
breakers options, single or dual (A/B) load
bus, and 600A carrying capacity per
panel. A digital meter monitors voltage
and current of each load bus.
Fuse / Circuit Breaker Panels
Distribution protector options include:
• 6 position GMT bullet fuseholder
• 6 position 0-125A TPS/TLS fuseholder
• 14 position 0-250A circuit breakers for
• 22 position 0-250A circuit breakers for
19” wide panels
23” wide panels
Micro-BDCBB Secondary DC Distribution
• Ideal for customer premise
• Digital meter interface
• 600 Amp capacity panels in a
• Small power distribution from
VIM 1 Intelligent Meter
The VIM 1 digital meter includes an
audible alarm with a user configurable
on/off feature. There is a form-C relay
for each of the three alarms for remote
monitoring - power loss/under voltage,
current overload/threshold exceeded,
and blown fuse/breaker trip. There are
two RJ45 type connectors on the board
that allow multiple VIM 1 boards to be
daisy chained together for network
connectivity.
power applications
compact 4 RU size
battery plant to load equipment
© 2010 Lineage Power. All rights reserved.
Benefits
Reliability
– Delivers decades of service
– High availability architecture
– NEBS level 3 certified
Intelligence
– Industry leading digital smart monitor
– Network interface for remote access
– Visual, audible and remote alarms
Investment Protection
– Backward compatibility
– Flexible upgrade options
– Seamless integration with GPS plants
On Time Delivery
– Standard building blocks
– 4 - 6 week availability
– 24/7 support
Total Efficiency
The Lineage Power Total Efficiency™
(TE) architecture reduces energy loss
and lowers cooling costs by 50-70%.
TE products will prioritize sustainable
energy sources like solar, wind, water
and fuel cells over traditional utility grid
or diesel generator sources – and they
will intelligently respond to smart grid
information to reduce consumption
during peak demand periods. Active
Rectifier Management (ARM) and
Battery Charging Optimization (BCO)
features increase efficiency on current
and legacy power infrastructures. The
Total Efficiency architecture addresses
issues end-to-end based on our proven
experience and expertise in batteries,
power distribution, DC energy systems,
AC/DC power supplies, and DC/DC
board mounted power to deliver a
solution that is more safe, reliable and
energy efficient than alternatives from
our competitors.
P R O D U C T O V E R V I E W

Related parts for micro-bdcbb

micro-bdcbb Summary of contents

Page 1

... Micro-BDCBB -48V DC Battery Distribution Circuit Breaker Bay Overview The Lineage Power Micro-BDCBB serves as a secondary power distribution center for - power delivered from a battery plant to the load equipment. The configuration is versatile with fuse or circuit breakers options, single or dual (A/B) load bus, and 600A carrying capacity per panel ...

Page 2

... Canada/US UL60950/UL1801 CE CE mark EMI/EMC CISPR class A conducted and radiated Outline Drawing 01/10 Micro-BDCBB Secondary DC Distribution 23” DC Distribution Panel with 477C alarm card © 2010 Lineage Power. All rights reserved Page 2 ...

Page 3

... Outline Drawings CC848786401 Wall Mounting Bracket for any Panel 01/10 Micro-BDCBB Secondary DC Distribution 19” Micro-BDFB with smart meter © 2010 Lineage Power. All rights reserved. Page 3 ...

Page 4

... Outline Drawings 01/10 Micro-BDCBB Secondary DC Distribution Accessory Items for ED83368-30 Panels © 2010 Lineage Power. All rights reserved. Page 4 ...

Page 5

... Group 4: 19” Micro-BDCBB, dual bus, dual shunt, smart meter, 14 breaker/fuse positions Group 6: 23” Micro-BDCBB, single bus, single shunt, smart meter, 22 breaker/fuse positions Group 8: 19” Micro-BDCBB, single bus, single shunt, smart meter, 14 breaker/fuse positions Bracket for mounting panels to a wall. ...

Page 6

... Fuse Puller Misc Replacement Parts Digital Meter Replacement * Maximum of 3 125A fuses per side. A space must be left between each fuse. 01/10 Micro-BDCBB Secondary DC Distribution Photo © 2010 Lineage Power. All rights reserved. Ordering Comcode ...

Page 7

... Notes: ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... ......................................................................................................................................................................................................................... 01/10 Micro-BDCBB Secondary DC Distribution © 2010 Lineage Power. All rights reserved. Page 7 ...

Page 8

... Lineage Power reserves the right to change specifications without notice. Please contact your Lineage representative to confirm current specifications. Please visit www.lineagepower.com/patents for patents and trademark information. 01/10 Micro-BDCBB Secondary DC Distribution Service & Support Lineage Power field service and support personnel are trusted advisors to our customers – always available to answer questions and help with any project, large or small ...