CONTACT ELECTRICAL CHARACTERISTICS
Date of issue: 9/07
Minimum
operating cycles
ENGINEERING DATA SHEET
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Featuring
www.esterline.com
100,000 cycles
100,000 cycles
100,000 cycles
400,000 cycles
20,000 cycles
APPLICATION NOTES:
001
002
007
023
APPLICABLE SOCKETS:
S300
SC30*
50 cycles
LEACH
©
power and control solutions
Contact rating per
pole and load type
resistive load
inductive load (L/R=5ms)
motor load
lamp load
resistive overload
at 25% rated resistive load
Polarized, non latching hermetically sealed relay
Contact arrangement
Coil supply
Meets the requirements of
Qualified to
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
Weight
Dimensions max.
of case in mm
Balanced Force design.
Hermetically sealed, corrosion protected metal can.
Intrinsically safe relay.
@28 Vdc
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
- 101 -
10
40
8
4
2
@115 Vac 400 Hz
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
Load Current in Amps
10
60
HERMETICALLY SEALED RELAY
8
4
2
2 PDT
Direct current
MIL-R-83536/9 and /10
CECC16101-018
CECC16303-801
10 Amps / 28 Vdc or 115 Vac -
400 Hz
40 grams max
26 x 25.7 x 13.3
@115/200 Vac 400 Hz 3Ø
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
2 PDT/10 AMP
10
8
4
2
Page 1 of 4
M300

Related parts for m300-d1n

m300-d1n Summary of contents

Page 1

... Buena Park, CA 90622 France . . . . Tel: (01) 714-736-7599 Tel: (33 Fax: (01) 714-670-1145 Fax: (33 101 - M300 2 PDT/10 AMP 2 PDT Direct current MIL-R-83536/9 and /10 CECC16101-018 CECC16303-801 10 Amps / 28 Vdc or 115 Vac - 400 Hz 40 grams max 26 x 25.7 x 13.3 @115/200 Vac 400 Hz 3Ø ...

Page 2

... VRMS / 50 Hz 1000 VRMS / 50 Hz 350 VRMS / 50 Hz 100 M 30G / 75 to 3000 Hz 20G 75 to 3000 Hz 200G / 6 ms 100G / µ max 10 ms max 1 ms max 150 mV max 175 mV max - 102 - M300 110 29 50 125 19.8 34 320 ...

Page 3

... SILICON GASKET SHORE A 15-30 GOLD PLATED PINS - 103 - D 1 ±0.1 7.5 ±0.15 4 ±0.15 4 3.8 35.5 36.7 44 MAX M3.5 OR 6.32 UNC 2A 1.2 9.5 0.8 MAX MAX G : UNC R : ISO M3.5 Ø8 MAX = = = = = 15.9 5.08 5.08 5 5.08 +0.5 3.6 +0 5.08 ISOLATION PAD 10114 BENT TIN SHORT TIN PLATED PINS PLATED PINS M300 M3 9 15.9 1.27 Page ...

Page 4

... L/R ratio for all types of DC coils is Life expectancy for loads other than 28Vdc: See application note no. 002 G Date of issue: 9/07 BOTTOM VIEW, DE-ENERIZED COIL CE : EXPORTED SPIKES 104 - N COIL 1 - +X1 SUPPRESSOR DEVICE M300 M300 Page ...

Page 5

Application notes CORRECTION DUE TO COIL COPPER WIRE RESISTANCE 1.8 1.6 1.4 1.2 1 0.8 0.6 -80 -30 Nominal Resistance at 25°C Example: Coil resistance at 25°C: 935 ohms. What 125°C? Correction coefficient on diagram is: 1.39 ...

Page 6

Application notes Date of issue: 6/00 LIFE CAPABILITY VERSUS VOLTAGE - 2 - N°002 Page ...

Page 7

Application notes Date of issue: 6/00 LIFE CAPABILITY VERSUS VOLTAGE - 3 - N°002 Page ...

Page 8

Application notes The inductive nature of relay coils allows them to create magnetic forces which are converted to mechanical movements to operate contact systems. When voltage is applied to a coil, the resulting current generates a magnetic flux, creating mechanical ...

Page 9

Types of suppressors: Passive devices. The resistor capacitor circuit It eliminates the power dissipation problem, as well as fast voltage rises. With a proper match between coil and resistor, approximate capacitance value can be calculated from 0.02xT/R, where ...

Page 10

The bifilar coil The principle is to wind on the magnetic circuit of the main coil a second coil shorted on itself proper adaptation of the internal resistance of this second coil it is possible to find an ...

Page 11

The diode + resistor network It eliminates the inconvenience of the resistor alone, explained above, and it limits the action of a single diode now preferred to used the diode + zener network. The diode + zener network ...

Page 12

Application notes Definition and applicability This application note defines the minimum distance between relays to maintain the whole performances of the relays as given in our data sheets. Phenomenon analysis Each relay generates a magnetic field either when relay is ...

Page 13

... Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component. Date of issue: 12/09 BASIC SOCKET SERIES DESIGNATION FOR: Series M300 (DC Coil), M301 (DC Coil), M302 (DC Coil), FD300, FLS300, FLR300 M 22520/2-01 with turret M 22520/2-14. M 81969/14-01. M 22520/1-01 with turret M 22520/1- 3191-1. ...

Page 14

... TERMINAL LAYOUT CODE A S300 POSITION, TOLERANCE SEE CODE B FOR M300 RELAY CODE B S301 DETAIL 15.24 10.16 5. 12.68 FOR M301 RELAY, FOR K COIL MOUNTING HARDWARE CODE 1 : 05-284-12 LOOSE UNC HARDWARE BOTTOM MOUNT MOUNTING TORQUE NUT 4/40:0,45 ±0,1 Nm NUT 10-32:1,2 MAX :3,6 mm BOTTOM MOUNT MOUNTING TORQUE:0,45 ± ...

Page 15

WIRE INSULATION DIAMETER FOR SEAL TO GROMMET Code A Recommended for contact code 2 contact code 8 Dia: 1.2 ......2.6mm (Y1-Y2) Dia: 0.8....1.4mm CONTACT SIZE AND STYLE Y1-Y2 Crimp end to accomodate AWG22-24 05 912 00 (for product code 2+3) ...

Page 16

... Loose terminals Above/below M 301-D4F/-K panel mounting M 301-D4E/-J Applicable for relays M300-D4A /-L/-N/-B/-C Loose terminals below M 301-D4F/-K panel mounting M 301-D4E/-J Applicable for relays M300-D4A /-L/-N/-B/-C Loose terminals M301-D4F/-K Above/below panel mounting M301-D4F/-J M302-D4A/ -L/-N/-B/-C M300-D4A /-L/-N/-B/-C Fixed terminals M 301-D4F/-K Above/below panel mounting M 301-D4E/-J M 302-D4A/ -L/-N/-B/-C Page ...

Page 17

... Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component. Date of issue: 3/06 SNAP AND LOCK SOCKET SERIES DESIGNATION FOR: SERIES M300, M301, M302, M400, M401, M402, T402, T412 DESIGNED TO THE STANDARDS AND REQUIREMENTS OF: 2-pole, 10A relays ...

Page 18

SOCKET DIMENSIONS RELAY GASKET SUPPLIED WITH RELAY 5.0 TERMINAL LAYOUT SC301-2 Date of issue: 3/06 MTG SCREW PHILLIPS HEAD WASHER SPACER PANEL .064±.005 THICK SOCKET RECOMMENDED MOUNTING PANEL CUTOUT WIRE SEALING GROMMET 5.0 13.21 MAX 2.54 35.7 SC301 ...

Page 19

SOCKET DIMENSIONS GASKET SUPPLIED WITH RELAY 5.08 TYP 15.8 TERMINAL LAYOUT SC400 Date of issue: 3/06 RELAY MTG SCREW PHILLIPS HEAD WASHER SPACER 15.8 PANEL .064±.005 THICK SOCKET WIRE SEALING GROMMET RECOMMENDED MOUNTING PANEL CUTOUT 2.54 5.08 TYP 25.4 MAX ...

Page 20

... SOCKET NUMBERING SYSTEM 1-Basic socket snap lock designation______________| 2-Mating relay (M300, M301, M302, M400, M401__________| 2-Hardware (0=less hardware, 1=with hardware)_____________|| 3-Contacts (0=less contacts, 1=with contacts)______________| Date of issue: 3/06 SC 300 SERIES SC30* Page ...

Related keywords