e5cs-rtu-w Omron Corporation, e5cs-rtu-w Datasheet
e5cs-rtu-w
Related parts for e5cs-rtu-w
e5cs-rtu-w Summary of contents
Page 1
... Ordering Information when ordering. Examples • Relay control output, without alarm, thermocouple input, plug-in construction, light gray case: E5CS-RKJU-W • Relay control output, one alarm output, platinum resistance thermometer input, plug-in construction, light gray case: E5CS-R1PU-W Refer to E5CS/E5CSV Operation for operating procedures. ...
Page 2
... E5CS-RKJDU-W E5CS-RPDU-W E5CS-QKJDU-W --- E5CS-R1KJDU-W E5CS-R1PDU-W E5CS-Q1KJDU-W --- Model with thermistor Model with universal- input (thermocouple and platinum resistance thermometer) E5CS-RGU-W E5CS-RTU-W E5CS-QGU-W E5CS-QTU-W E5CS-R1GU-W E5CS-R1TU-W E5CS-Q1GU-W E5CS-Q1TU-W --- E5CS-R2TU-W E5CS-Q2TU-W Model with thermistor E5CS-RGDU-W E5CS-R1GDU-W Type Model P2CF-11 P3GA-11 P2CF-11-E ...
Page 3
... Ambient operating temperature Ambient operating humidity 25% to 85% −25 to 65°C (with no condensation or icing) Storage temperature Note: Do not use an inverter output as the power supply. (Refer to Safety Precautions for All Temperature Controllers.) E5CS Pt100, JPt100 E52-THE@@ 3 ...
Page 4
... The following exception applies to platinum resistance thermometers. • Input set values 1 for E5CS- ±1 digit max. 3. The following exceptions apply to thermistors. • When the unit setting is °C, temperature indication ranges exceeding the set temperature range ±10% FS may not be accurate. ...
Page 5
... E5CS 500 0 9 The shaded value indicates the default setting status. 199.9 0.0 9 The shaded value indicates the default 0.1°C setting status. E52.) 4 kΩ (200°C) 300 150 9 The shaded value indicates the default setting status ...
Page 6
... Otherwise, unwanted current paths will cause measurement errors. 2. Models with 100 to 240 VAC and 24 VAC/VDC are separate. Models using 24 VDC have no polarity sure to check the sensor type before using multi-output (thermocouple/platinum resistance thermometer) models. Nomenclature E5CS-U Plug-in Models Temperature display Deviation indicators Mode indicators ...
Page 7
... E5CS-U + Adapter for Flush Mounting (Enclosed) + Back Connecting Socket (Order Separately) (Without Alarms) E5CS-U + Adapter for Flush Mounting (Enclosed) + Back Connecting Socket (Order Separately) (With Alarms) Note: Use the P2CF-08 and P3G-08 Sockets for models without alarms, and use the P2CF-11 and P3GA-11 Sockets for models with alarms. ...
Page 8
... P3GA-11 Back Connecting Socket Note: Do not use any other types of Sockets. Doing so will adversely affect the accuracy. Applicable Thermistors Use Element Interchangeable Thermistors (E52-THE5A, E52- THE6D, and E52-THE6F) to connect to the E5CS-@GU. For details on Sensors, refer to E52. Terminal Arrangement/ Eight, M3.5 × 7.5 sems screws 7 ...
Page 9
... Safety Precautions Refer to Safety Precautions for All Temperature Controllers. Refer to E5CS/E5CSV Operation for operating procedures. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. ...
Page 10
... OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ Read and Understand This Catalog Warranty and Limitations of Liability Application Considerations Disclaimers In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2009 All Right Reserved. 2009.1 ...