h5s-yb4d-x Omron Corporation, h5s-yb4d-x Datasheet

no-image

h5s-yb4d-x

Manufacturer Part Number
h5s-yb4d-x
Description
Digital Time Switch
Manufacturer
Omron Corporation
Datasheet
Easier, More Convenient Time Switches, with
New 4-circuit Output and Yearly Models in
Addition to 2-circuit Weekly Models
• Independent Day Keys provide easier operation.
• Temporary holiday setting function makes it easy to turn OFF
• Settings can be made even with the Time Switch turned OFF.
• Test mode enables easy program checking.
• Complies with EMC Directives, UL/CSA, and other safety
• Includes summer time (DST) adjustment.
• Set value can be changed both upward and downward for
• Integrated temperature compensation circuit helps keep
• Includes time counter and total counter functions with alarm
• Bank function allows program switching by an external input.
• New 4-circuit output models with a compact, 72 × 72-mm DIN
Note: 1. Available only on yearly models.
Features
Easier and More Convenient to Use
■ Simple Setting
■ Convenient Functions
Time Counter/Total Counter Functions (See note.)
This function makes it possible to monitor the total time that a load
has been applied, or the total number of operating cycles. It allows
the Time Switch to be used for managing maintenance.
output for holidays and non-operating days.
standards.
Yearly models also offer automatic switching to DST.
speedier setting.
accurate time over a wide temperature range. (See note 1.)
indicator. (See note 2.)
(See note 3.)
size added to the series.
Digital Time Switch
H5S
Independent Day Keys make setting easy.
2. Available only on 2-circuit models.
3. Available only on weekly models.
With alarm indicator
Shows total lamp ON time
Up/down set value changing
for speedy setting.
Temporary holidays
(non-operating days)
are also easy to set.
Weekly models: Specify the day.
Yearly models: Specify the date.
Time Adjustment Function (See note.)
The time can be set to 00 min 00 s by using an external input. The
times on multiple Time Switches can also be easily synchronized.
Note: Equipped on 2-circuit models.
Master
Slave
Synchronized!
Slave
CSM_H5S_DS_E_3_1
1

Related parts for h5s-yb4d-x

h5s-yb4d-x Summary of contents

Page 1

... Time Switch to be used for managing maintenance. With alarm indicator Shows total lamp ON time Time Adjustment Function (See note.) The time can be set to 00 min using an external input. The times on multiple Time Switches can also be easily synchronized. Synchronized! Slave Slave Master Note: Equipped on 2-circuit models. CSM_H5S_DS_E_3_1 1 ...

Page 2

... Model Number Structure ■ Model Number Legend Note: This model number legend includes combinations that are not available. Please check the “List of Models” for availability. H5S- @@@@@ - @ Control cycle ...

Page 3

... Approx. 3 264 VAC 60 Hz Approx. 0 28.8 VDC H5S Models H5S-WB2 H5S-WB2D H5S-WFB2 H5S-WFB2D H5S-YB2-X H5S-YB2D-X H5S-YFB2-X H5S-YFB2D-X H5S-YB4-X H5S-YB4D-X H5S-YFB4-X H5S-YFB4D-X Yearly 4-circuit Models (H5S-Y@4) Approx. 3 264 VAC 60 Hz Approx. 1 28.8 VDC SPST-NO × 4 circuits 250 VAC 250 VAC (cosφ = 0.4) 3 ...

Page 4

... EN 60730-2-7 (IEC 61000-4-5 line to line (power line, output line line to ground (power line, output line) 0.5 kV line to line (input line line to ground (input line) EN 60730-2-7 (IEC 61000-4-11): 0.5-s cycle, 100% (rated voltage) H5S Yearly 4-circuit Models (H5S-Y@4) 4 ...

Page 5

... Adds a yearly timer operation to the weekly timer program. For details, refer to About Yearly Programs on page 18. Adds a yearly pulse-output operation to the weekly pulse-output program. For details, refer to About Yearly Programs on page 18. --- H5S Yearly 4-circuit Models (H5S-Y@4) 48 steps/circuit (See note 2.) 12 steps/circuit (per season) (See note 3.) Yearly 4-circuit Models (H5S-Y@4) 5 ...

Page 6

... The display illumination will turn OFF when there has been no operation for 2 min. The display will light again when any key other than a slide switch is pressed for at least 1 s. • No output will be generated. Yearly 2-circuit Models (H5S-Y@2) --- --- --- --- Allows weekly programs to be automatically switched in response to seasons throughout the year. For details, refer to Season Switching/Period of Season (F8/F9) on page 24. H5S Yearly 4-circuit Models (H5S-Y@4) 6 ...

Page 7

... Connections ■ Terminal Arrangement H5S-@A@/-@B@ Flush Mounting Models Two-circuit Models Output 2 Input (Rear View − ∼ ∼ Power Output 1 source H5S-@FA@/-@FB@ Surface Mounting Models Two-circuit Models Input Output (Front View − ...

Page 8

... Used to specify the date (yearly models only) Switch • In RUN mode, these keys are used to shift the Time Switch to the Checking the Settings mode. 2. Holiday/ Select Program/ Down Key 3. Write Key 4. m/Pulse Key 5. h Key 6. Reset Key 7. +1h/Clear Key H5S Functions 8 ...

Page 9

... Displays the current day or the day set for an operation. 4. Main display 18 Displays the number of the circuit (output) for 5. Pulse width unit which output is ON. indicator 7. Display of number of remaining steps 8. Set circuit number indicator 9. Sub-display 2. AM/PM indicator 10. Timing chart display 15. Year indicator H5S Function 9 ...

Page 10

... When using the product in an exposed mounting condition, always use the Y92A-72H Large Terminal Cover (order separately) to comply with Electrical Appliance and Material Safety Law (for Japan). Y92A-72H Large Terminal Cover (Order separately) H5S Panel Cutout + 0 0 9.5 49 Mounting panel Note: Panel thickness ...

Page 11

... The numbers in parentheses ( ) are dimensions for the PFP-50N End Plate PFP-M M4 × 8 pan-head screw 50 11 spring washer DIN Track Mounting Base Y92F-90 Note: The DIN Track Mounting Base can be used only with the surface mounting models (H5S-@FA@/-@FB@). PFP-100N2 7.3 ±0.15 4.5 35 ±0.3 27 ±0. ...

Page 12

... Depending on the power supply capacity, operation may not start. Be sure to use a power supply with a sufficient capacity. 2. Inrush current generated by turning ON or OFF the power supply may deteriorate contacts on the power supply circuit. Use to turn ON or OFF devices with a rated current min. H5S 12 ...

Page 13

... Voltage (SELV) circuit is desired, supplementary insulation must be provided. • Use crimp type cable lug terminals with insulating sleeves for wiring. • Be sure to mount a surface-mounting model (H5S-@FA@/-@FB enclosure. Basic Use Prior to Using Before setting the parameters necessary for each operation, the operation of each circuit (output) must be determined. Begin by setting initial setting mode as required ...

Page 14

... Yearly, 4 Circuits P1 PRGM P2 RUN RUN Shaded portion indicates blinking of the indicator. 2 circuits 4 circuits for more and enter the settings, h and m Keys rapidly advances the value. decrements the value of the key that was last is pressed again before , the setting is H5S 14 ...

Page 15

... Set the OFF time with 4. Press WRITE *1 If one or more programs have already been set, the display starts showing the set programs. To add another program, press is displayed. *2 Holding down the Pressing pressed. H5S Yearly, 2 Circuits Yearly, 4 Circuits TUE WED THU FRI SAT 17:15 Number of ...

Page 16

... SUN MON TUE WED THU FRI SAT . PLS . *2 SUN MON TUE WED THU FRI SAT to enter the settings. WRITE repeatedly until “--:--“ h and m Keys rapidly advances the value. decrements the value of the key that was last in program setting mode. WRITE H5S SAT Number of remaining steps 16 ...

Page 17

... TIMER and PULSE positions after the data has been set. Stop 19:00 Number of Shaded portion remaining steps indicates blinking of the indicator. SUN MON TUE WED THU FRI SAT SUN MON TUE WED THU FRI SAT SUN MON TUE WED THU FRI SAT H5S 17 ...

Page 18

... Example: Extend ordinary weekly operation from 18:00 to 22:15 on March 25 only. Weekly Program Yearly Program Output performance of H5S Note: 1. This example combines the following programs. For details on yearly programming, refer to page 19. Weekly program Friday, Saturday, and Sunday: 9:00 (ON time), Yearly program March 25: 18:00 (ON time), 22:15 (OFF time) CLEAR 2 ...

Page 19

... SUN MON TUE WED THU FRI SAT for more. (The remaining steps h and PLS . to enter the settings. WRITE repeatedly until “--:--“ is displayed. decrements the value of the key that was last pressed. in yearly program setting mode. H5S Number of 19 ...

Page 20

... M , and (The year can . and to enter the settings. for more to return to RUN mode. WRITE repeatedly until “--.--“ is decrements the value of the key that was last pressed. for holiday setting mode to return to RUN H5S 20 ...

Page 21

... SUN MON TUE WED THU FRI SAT ) at the position SUN MON TUE WED THU FRI SAT to enter the setting. Yearly, 2 Circuits Yearly, 4 Circuits is pressed for more in RUN mode, the current SUN MON TUE WED THU FRI SAT H5S 21 ...

Page 22

... Return the Output ON/OFF Switch from ON to AUTO with WRITE pressed. (Output remains in the ON state.) 3. The regular operation will be performed from the next OFF time. Total count cnt (See note.) H5S Yearly, 2 Circuits Yearly, 4 Circuits WRITE . (Output remains in the OFF ...

Page 23

... Using Advanced Functions About Advanced Functions Set the advanced functions as required to perform more advanced operation. Outlines of the advanced functions are provided on the following pages. Refer to the Instruction Manual enclosed with the H5S for details. Initial Setting Mode Weekly, 2 Circuits Yearly, 2 Circuits Yearly, 4 Circuits ...

Page 24

... Press or display to sync. 2. Press WRITE Manual Operation on Recovery from Power Failure (F2) Weekly, 2 Circuits Yearly, 2 Circuits After power is restored to the H5S possible to set the Time Switch to stop turning ON output until external input is applied. Power supply External input Output ON OFF Flashing ...

Page 25

... Parameters : Manual adjustment off auto: Automatic adjustment (Select summer time schedule in F7.) Note: The inverted characters Setting method Shaded portion indicates blinking of the indicator. to enter the setting. H5S Yearly, 4 Circuits indicate the default. 1. Press select one of the parameters. 2. Press WRITE to enter the setting ...

Page 26

... In the interest of product improvement, specifications are subject to change without notice. Summer time end date and time At 2:00 on the first Sunday in November At 3:00 on the last Sunday in October At 3:00 on the last Sunday in March to select one of the m to enter the setting. Remedy Press “RESET” Press “RESET” H5S 26 ...

Page 27

... OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ Read and Understand This Catalog Warranty and Limitations of Liability Application Considerations Disclaimers In the interest of product improvement, specifications are subject to change without notice. (c)Copyright OMRON Corporation 2008 All Right Reserved. 2008.11 ...

Related keywords