1/32 DIN with Communications Function
• Various temperature inputs: Thermocouple, platinum resistance
• Auto-tuning and self-tuning available. Auto-tuning is possible
• Heating or heating/cooling control is available.
• Water-resistant construction (NEMA4X: equivalent to IP66).
• Conforms to UL, CSA, and IEC safety standards as well as CE
Model Number Structure
■ Model Number Legend
1. Output type
2. Number of alarms
3. Communications
Ordering Information
■ Standard Models
Note 1. If the heating/cooling function is used, ALM1 will be used for control output and so alarm output will not be available.
E5GN- @ @ @ @ - @ @
1/32 DIN
48(W)
thermometer, infrared temperature sensor, and analog inputs.
even while self-tuning is being executed.
marking.
Digital Temperature Controllers
E5GN
R:
Q:
Blank: No alarm
1:
Blank: No communications function
03:
2. Control output 2 for heating/cooling control is relay output.
3. Specify the power supply specifications when ordering.
Refer to the “Safety Precautions” on page 16.
24(H)
Relay
Voltage (for driving SSR)
One alarm
RS-485
1 2
Size
100(D) mm
3
4
5 6
100 to 240 VAC
24 VAC/VDC
Power supply
voltage
---
1
(see note 1)
---
1
(see note 1)
No. of alarm
points
Relay
Voltage (for driving SSR) E5GN-QTC AC100-240
Relay
Voltage (for driving SSR) E5GN-Q1TC AC100-240 E5GN-Q1P AC100-240
Relay
Voltage (for driving SSR) E5GN-QTC AC/DC 24
Relay
Voltage (for driving SSR) E5GN-Q1TC AC/DC 24
Control output
4. Input type
5. CompoWay/F serial communications
6. Power supply
TC:
P:
Blank: Not available
FLK: CompoWay/F serial communications
AC100-240: 100 to 240 VAC
AC/DC 24: 24 VAC/DC
Digital Temperature Controllers
Thermocouple
Platinum resistance thermometer
48(W) × 24(H) × 100(D) mm
E5GN-RTC AC100-240
E5GN-R1TC AC100-240 E5GN-R1P AC100-240
E5GN-RTC AC/DC 24
E5GN-R1TC AC/DC 24
Thermocouple model
E5GN-RP AC100-240
E5GN-QP AC100-240
E5GN-RP AC/DC 24
E5GN-QP AC/DC 24
E5GN-R1P AC/DC 24
E5GN-Q1P AC/DC 24
E5GN
Platinum resistance
thermometer model
1

Related parts for e5gn-rtcac100-240

e5gn-rtcac100-240 Summary of contents

Page 1

... Relay E5GN-RTC AC100-240 Voltage (for driving SSR) E5GN-QTC AC100-240 1 Relay E5GN-R1TC AC100-240 E5GN-R1P AC100-240 (see note 1) Voltage (for driving SSR) E5GN-Q1TC AC100-240 E5GN-Q1P AC100-240 --- Relay E5GN-RTC AC/DC 24 Voltage (for driving SSR) E5GN-QTC AC/ Relay E5GN-R1TC AC/DC 24 (see note 1) Voltage (for driving SSR) E5GN-Q1TC AC/DC 24 ...

Page 2

... Multi SP, SP ramp, MV limiter, input digital filter, self-tuning, input shift, run/stop, protection func- tions, etc. – (with no condensation or icing) 25% to 85% – (with no condensation or icing) E5GN Thermocouple model Platinum resistance thermometer model E5GN-R03TC-FLK E5GN-R03P-FLK AC100-240 AC100-240 E5GN-Q03TC-FLK E5GN-Q03P-FLK AC100-240 AC100-240 E5GN-R03TC-FLK E5GN-R03P-FLK AC/DC 24 AC/DC 24 E5GN-Q03TC-FLK E5GN-Q03P-FLK AC/DC 24 AC/ VAC, 50/60 Hz/24 VDC 4 VA/2.5 W ...

Page 3

... Digital Temperature Controllers ES1B Infrared Analog input Temperature Sensor 115 to 140 120 C 165 5C 260 C 1800 Usable in the following rang scaling: 1999 to 9999 or 199.9 to 999.9 260 120 165 70 100 E5GN 3 ...

Page 4

... The alarm value is set deviation from the set point. Alarm value = Set point 100 C/ F E5GN When X is negative * Example When the absolute-value alarm is selected (For alarm types 8 to 11) The alarm value is set as an absolute value from the alarm value of 0 C/F ...

Page 5

... V: (0. MHz) Voltage Dip/Interrupting Immunity: IEC 61000-4-11 0.5 cycle, 100% (rated voltage) Radiated Emission: EN 61326 Class A Conducted Emission: EN 61326 Class A UL 61010C-1 (Listing) CSA C22.2 No. 1010.1 (Evaluated by UL.) EN 61010-1: 2001 IEC 61010-1: 2001 Digital Temperature Controllers 2 ) Mounting bracket: approx E5GN 5 ...

Page 6

... I/O section. Alarm output/control output 2/input error output Analog input Thermocouple RS- Infrared temperature sensor 485 TC Temperature-resistance Host Pt thermometer Analog input E5GN Two input power supplies are available: 100 to 240 VAC or 24 VAC/VDC (no polarity). ...

Page 7

... To mount the E5GN so that it is waterproof, insert the waterproof packing onto the E5GN. When two or more E5GN Controllers are mounted, make sure that the surrounding temperature does not exceed the allowable operating temperature given in the specifications. ...

Page 8

... Each press of this key increases values displayed on the No.2 display. Holding down this key continuously increases values. Down Key Each press of this key decreases values displayed on the No.2 display. Holding down this key continuously decreases values. Level + Mode Key This key combination sets the E5GN to the "protect level." ...

Page 9

... Note that control is stopped when these four levels are selected. When switched back to the operation level from one of these levels, control will start. 2. For the calibration mode, refer to the relevant User's Manual the E5GN, the Control in progress Control stopped Level change Protect Level To select this level, simultaneously press the least 3 seconds ...

Page 10

... Level change cntl onof s-hc stnd st cp c-cp ore? or-r alt1 amo? To return to the operation level, press the second. E5GN Input type 0 Scaling upper limit Scaling lower limit 0 Decimal point 0 Temperature unit upper limit Limit the set point. SP lower limit PID ON/OFF ...

Page 11

... 260 ( 500 ( F) One of following ranges depending on the re- sults of scaling: 1999 to 9999, 199.9 to 999.9 Input Temperature Range –200 to 850 ( C) /–300 to 1500 ( F) –199.9 to 500 /–199.9 to 900 0.0 to 100 /0.0 to 210 –199.9 to 500 /–199.9 to 900 0.0 to 100 /0.0 to 210 E5GN 11 ...

Page 12

... Data bits len 7 Stop bits sbit 2 Communications prty parity e?en E5GN O Press the key for at least 3 s. (Display flashes for at least 1 s.) Displays other than that for switching between automatic and manual Limit the set point. For input type of temperature, standard, or PID ...

Page 13

... Cooling c-sc coefficient 1.00 Dead band c c-db 0.0 Manual reset value of-r 50.0 Hysteresis (heating) c hys 1.0 Hysteresis (cooling) c chys 1.0 Digital Temperature Controllers SP used by multi-SP 1-point shift Set either of these parameters. 2-point shift PID settings Heating/cooling Clear the offset during stabilization control. Hysteresis settings E5GN 13 ...

Page 14

... This protect level protects setup from being changed by operating the keys on the front panel. Set value OFF display ON Default setting: OFF Set value Advanced function setting level X X E5GN Description Setup can be changed by key operation. Setup cannot be changed by key operation. (The protect level, can be changed.) ...

Page 15

... Communications Setting Level Set the E5GN communications specifications in the communications setting level. For setting communications parameters, use the E5GN panel. The communications parameters and their settings are listed in the following table. Parameter Displayed characters u-no Communications unit No. bps Baud rate len Data bits ...

Page 16

... Note SELV circuit is one separated from the power supply with double insulation or reinforced insulation, that does not exceed 30 V r.m.s. and 42.4 V peak or 60 VDC class 2 power supply is one tested and certified have the current and voltage of the secondary output restricted to specific levels. E5GN ...

Page 17

... When starting operation after the Temperature Controller has warmed up, turn OFF the power and then turn it ON again at the same time as turning ON power for the load. (Instead of turning the Temperature Controller OFF and ON again, switching from STOP mode to RUN mode can also be used.) Digital Temperature Controllers E5GN 17 ...

Page 18

... These devices can cause radio disturbances which adversely affect the performance of the Controller. Mounting 1. Insert the E5GN into the mounting hole in the panel from the front. 2. Push the adapter along the E5GN body from the terminals up to the panel, and secure it temporarily. ...

Page 19

... Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. 5. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. Digital Temperature Controllers E5GN 19 ...

Page 20

Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at www.omron.com/oei – under the “About Us” tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply ...

Related keywords