g5v-1 Omron Corporation, g5v-1 Datasheet

no-image

g5v-1

Manufacturer Part Number
g5v-1
Description
Low Signal Relay
Manufacturer
Omron Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G5V-1
Manufacturer:
OMRON
Quantity:
5 510
Part Number:
G5V-1
Manufacturer:
WINBOND
Quantity:
5 510
Part Number:
G5V-1
Manufacturer:
OMRON
Quantity:
704
Part Number:
G5V-1
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Part Number:
g5v-1 12VDC
Manufacturer:
OMRON
Quantity:
12 000
Part Number:
g5v-1 12VDC
Quantity:
500
Part Number:
g5v-1 3VDC
Manufacturer:
PANASONIC
Quantity:
12 000
Part Number:
g5v-1 9VDC
Manufacturer:
OMRON
Quantity:
12 000
Part Number:
g5v-1-12V
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Part Number:
g5v-1-12VDC
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Company:
Part Number:
g5v-1-12VDC
Quantity:
13 655
Part Number:
g5v-1-2-24VDC
Manufacturer:
OMRON/欧姆龙
Quantity:
20 000
Part Number:
g5v-1-24V
Manufacturer:
欧姆龙ORM
Quantity:
20 000
• High sensitivity: 150 mW nominal power consumption with
• Small size at 10 H x 7.5 W x 12.5 L mm (0.394 H x 0.295 W
• Conforms to FCC part 68 voltage surge.
• Fully-sealed construction.
• Ideal for use in telecommunications, security, and comput-
• RoHS Compliant.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-1-DC12).
Note: Reflow solder process version is also available in PCB through-hole configuration. Please consult your local Omron sales representative for
Specifications
■ Contact Data
■ Coil Data (G5V-1, G5V-1-2)
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23° C (73° F) with a tolerance of ±10%.
PCB through-hole
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
3
5
6
9
12
24
96 mW pickup power.
x 0.492 L in).
er/peripheral equipment.
Low Signal Relay
G5V-1
voltage
Rated
(VDC)
more information.
2. The operating characteristics are measured at a coil temperature of 23° C (73° F).
Terminal
Rated current
50
30
25
16.70
12.50
6.30
Load
(mA)
Standard
Special pickup
60
166.70
240
540
960
3,840
resistance
Coil
(Ω)
Type
0.50 A at 125 VAC, 1A 24 VDC
Ag (Au clad)
2 A
125 VAC, 60 VDC
1 A
62.50 VA, 30W
1 mA, 5 VDC
0.11
0.29
0.41
0.93
1.63
6.61
Armature OFF
Coil inductance
(Ref. value) (H)
Resistive load (p.f. = 1)
SPDT
Contact form
0.05
0.15
0.20
0.45
0.85
3.48
Armature ON
Single crossbar
80%
70%
(special pickup)
Contact type
Pick-up
voltage
Low Signal Relay
% of rated voltage
10% min.
Dropout
Inductive load (p.f. = 0.4, L/R = 7ms)
voltage
Fully sealed
Construction
200%
at 55° C
(131° F)
160%
at 70° C
(158° F)
Maximum
voltage
G5V-1
G5V-1
G5V-1-2
Approx. 150
consumption
Model
Power
(mW)
1

Related parts for g5v-1

g5v-1 Summary of contents

Page 1

... Conforms to FCC part 68 voltage surge. • Fully-sealed construction. • Ideal for use in telecommunications, security, and comput- er/peripheral equipment. • RoHS Compliant. Ordering Information To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-1-DC12). Terminal Type PCB through-hole Standard Special pickup Note: Reflow solder process version is also available in PCB through-hole configuration ...

Page 2

... Service life Mechanical Electrical Weight Note: Data shown are of initial value. ■ Characteristic Data Maximum switching capacity G5V-1 2 Low Signal Relay 100 mΩ max max. (mean value: approx. 2.50 ms max. (mean value: approx. 0.90 ms max. (mean value: approx. 0.17 ms) 36,000 operations/hour 1,800 operations/hour 1,000 MΩ ...

Page 3

... Dimensions Unit: mm (inch) ■ Relays G5V-1, G5V-1-2 ■ Approvals UL (File No. E41515)/CSA (File No. LR24825) Type G5V-1 SPDT G5V-1-2 Note the interest of product improvement, specifications are subject to change. 2. Complies with UL 1950 basic Insulation at 125 V (pollution degree 1 for internal spacings, pollution degree 2 for external spacings). ...

Page 4

... Product, nor to imply that any use listed may be suitable for any Product: (a) Outdoor use, use involving potential chemical contamination or electrical interference. (b) Use in consumer Products or any use in significant quantities. G5V-1 4 Low Signal Relay (c) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations ...

Page 5

... European Union's Directive on the Restriction of certain Hazardous Substances ("RoHS"), although the requirements of RoHS do not take effect until July 2006. These requirements may be subject to change. Please consult our website for current information. G5V-1 Low Signal Relay 5 ...

Page 6

... To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. J01C-E-01 01/07 G5V-1 6 Low Signal Relay OMRON ON-LINE Global - http://www.omron.com USA - http://www.components.omron.com Specifications subject to change without notice Printed in USA ...

Related keywords