MICS-5131 ETC2 [List of Unclassifed Manufacturers], MICS-5131 Datasheet
MICS-5131
Related parts for MICS-5131
MICS-5131 Summary of contents
Page 1
... High resistance to shocks and vibrations This Product Data Sheet accompanies MicroChemical Systems MiCS-5131 sensors for ethanol. Reproduction and distribution of this document is restricted by MicroChemical Systems. The following specifications are subject to change to accommodate continuous improvement. For this and other quality MiCS products, send an e-mail to • ...
Page 2
... Important Precautions: Please read the following instructions carefully before using the MiCS-5131 sensor described in this document to avoid erroneous readings and to prevent the device from permanent damage. • The sensor must not be wave soldered without protection or exposed to high concentrations of organic solvents, ammonia, or silicone vapors in order to avoid poisoning the sensitive layer. • ...
Page 3
... Cross Sensitivity: The following figure illustrates the MiCS-5131 cross sensitivity CO and CH4 CO C2H5OH H2 0.1 10 100 concentration [ppm] Fig. 4: Sensitivity to CO, H2, CH4, and C2H5OH at 25°C and 50% RH. Response time: A typical response curve under laboratory conditions is shown in figure 5 ...
Page 4
... Sensitivity Factor S is defined 60ppm of CO divided 23±2° C. MiCS-5131 Product Data Sheet Symbol Value / Range V 5 ...
Page 5
... Package Dimensions and Filter MiCS-5131 Product Data Sheet Dimension Min [mm] Max [mm 9.15 B 8.15 8.30 C 5.75 5.85 D 0.6 0.9 E 3.5 3.9 F 9.0 10.0 G 12.5 13.9 H 2.41 2.67 I 0.55 0.65 J 4.83 5.33 K 0.7 0.9 Page Doc NO: 0178 Rev ...