HCPL-2300-060 HP [Agilent(Hewlett-Packard)], HCPL-2300-060 Datasheet
HCPL-2300-060
Available stocks
Related parts for HCPL-2300-060
HCPL-2300-060 Summary of contents
Page 1
... ESD. • Microprocessor System Interfaces • Digital Isolation for A/D, D/A Conversion • RS-232-C Interface • High Speed, Long Distance Isolated Line Receiver Description The HCPL-2300/HCPL-0300 optocoupler combines an 820 nm AlGaAs photon emitting diode with an integrated high gain photon detector. This Functional Diagram ...
Page 2
... V (CMOS logic voltage). The Electrical and Switching Characteristics of the HCPL-2300/HCPL-0300 are guaranteed over a temperature range of -40°C to 85°C. This enables the user to confidently design a circuit which will operate under a broad range of operating conditions ...
Page 3
... TYPE NUMBER A XXXXZ YYWW 1.19 (0.047) MAX. 3.56 ± 0.13 (0.140 ± 0.005) 1.080 ± 0.320 (0.043 ± 0.013) 8-Pin DIP Package with Gull Wing Surface Mount Option 300 (HCPL-2300) 9.65 ± 0.25 (0.380 ± 0.010 1.19 (0.047) MAX. 1.080 ± 0.320 (0.043 ± ...
Page 4
... NOTES: THE TIME FROM 25 °C to PEAK TEMPERATURE = 8 MINUTES MAX 200 ° 150 °C smax smin Regulatory Information The HCPL-2300 has been approved by the following organizations: Insulation and Safety Related Specifications Parameter Min. External Air Gap (External Clearance) Min. External Tracking Path (External Creepage) Min ...
Page 5
... IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (HCPL-2300 Option 060 only) Description Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 300 V rms for rated mains voltage ≤ 450 V rms Climatic Classification Pollution Degree (DIN VDE 0110/1.89) Maximum Working Insulation Voltage ...
Page 6
DC Electrical Specifications For -40°C ≤ T ≤ 85°C, 4.75 V ≤ All typicals 25°C and unless otherwise specified. See note Parameter Symbol Min. Typ. Max. ...
Page 7
Package Characteristics For -40°C ≤ T ≤ 85°C, unless otherwise specified. All typicals Parameter Symbol Min. Input-Output Momentary V ISO Withstand Voltage* Resistance, Input-Output R I-O Capacitance, Input-Output C I-O *The Input-Output Momentary Withstand Voltage is a ...
Page 8
... Figure 5. Typical Propagation Delay vs. Temperature and Forward Current with and without Application of a Peaking Capacitor. HCPL-2300 HCPL-0300 Figure 8. Test Circuit for PHL PLH r Figure 6. Typical Propagation Delay vs. Forward Current. , and Figure 7. Typical Rise, Fall Time vs. Temperature. Figure 9. Typical Common Mode Transient Immunity vs ...
Page 9
... Open collector leakage current of 250 µA has been compensated by the 3.16 KΩ resistor (Figure 14) at the expense of twice the operating forward current. An application of the HCPL-2300/ HCPL-0300 as an unbalanced line receiver for use in long line twisted wire pair communication links is shown in Figure 15. Low ...
Page 10
... illustrated in Figure 19, an HCPL-2300/ HCPL-0300 Figure 14. Series Drive from Open Collector TTL/LSTTL Units. 10 optional V and GND trace can CC be located between the input and the output leads of the HCPL-2300/HCPL-0300 to provide additional noise immunity at the compromise of insulation capability (V ). I-O HCPL-2300/ HCPL-0300 ...
Page 11
... Figure 15. Application of HCPL-2300/HCPL-0300 as Isolated, Unbalanced Line Receiver(s). REFERENCE FIGURE 17 FOR DATA RATE vs. LINE DISTANCE L. Figure 16. Application of Two HCPL-2300/HCPL-0300 Units Operating as an Isolated, High Speed, Balanced, Split Phase Line Receiver with Significantly Enhanced Common Mode Immunity. REFERENCE FIGURE 17 FOR DATA RATE vs. LINE DISTANCE L. ...
Page 12
... Figure 17. Typical Point to Point Data Rate vs. Length of Line for Unbalanced (Figure 15) and Balanced (Figure 16) Line Receivers Using HCPL-2300/HCPL-0300 Optocouplers. RS-232-C SIGNAL 3 V – – -25 V Figure 18. RS-232-C Interface Circuit with HCPL-2300/ ° ° HCPL-0300 < T < Figure 19. Recommended Printed Circuit Board Layout. ...