HD6417618 RENESAS [Renesas Technology Corp], HD6417618 Datasheet - Page 387

no-image

HD6417618

Manufacturer Part Number
HD6417618
Description
32-Bit RISC Microcomputer SuperHTM RISC engine Family / SH7618 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417618RBGN100V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Bit
3
2
1
0
Bit Name
MCE
TFRST
RFRST
LOOP
Initial
value
0
0
0
0
R/W
R/W
R/W
R/W
R/W
Description
Modem Control Enable
Enables modem control signals CTS and RTS.
In synchronous mode, clear this bit to 0.
This bit is available only in SCFCR_0 and SCFCR_1. In
SCFCR_2, this bit is reserved. The initial value is 0 and
the write value should always be 0.
0: Modem signal disabled*
1: Modem signal enabled
Note: * The CTS signal is fixed active 0 regardless of
Transmit FIFO Data Register Reset
Disables the transmit data in the transmit FIFO data
register and resets the data to the empty state.
0: Reset operation disabled*
1: Reset operation enabled
Note: * Reset operation is executed by a power-on
Receive FIFO Data Register Reset
Disables the receive data in the receive FIFO data
register and resets the data to the empty state.
0: Reset operation disabled*
1: Reset operation enabled
Note: * Reset operation is executed by a power-on
Loop-Back Test
Internally connects the transmit output pin (TxD) and
receive input pin (RxD) and enables loop-back testing.
0: Loop back test disabled
1: Loop back test enabled
Section 14 Serial Communication Interface with FIFO (SCIF)
the input value, and the RTS signal is also
fixed 0.
reset.
reset.
Rev. 6.00 Jun. 12, 2007 Page 355 of 610