HD6417729 HITACHI [Hitachi Semiconductor], HD6417729 Datasheet - Page 229

no-image

HD6417729

Manufacturer Part Number
HD6417729
Description
Hitachi Microcomputer Development Environment System
Manufacturer
HITACHI [Hitachi Semiconductor]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417729F133A
Manufacturer:
HITACHI
Quantity:
5
Part Number:
HD6417729F133B
Manufacturer:
RENESAS
Quantity:
28
Part Number:
HD6417729F133B
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417729F133B
Manufacturer:
HITACH
Quantity:
20 000
Part Number:
HD6417729F133BV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417729R
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6417729RSH3-DSP
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
8. When the [Physical] option is selected in the [Memory area] group box in the [General] page
9. When the [Virtual] option is selected in the [Memory area] group box in the [General] page of
10. An address (physical address) to which a breakpoint is set is determined when the breakpoint
11. When a breakpoint is set to the cacheable area, the cache block containing the breakpoint
12. Note on DSP repeat loop:
6.5.6
1. Break Condition 2 is disabled during step execution.
2. Break Condition 2 is disabled when an instruction to which a BREAKPOINT has been set is
3. When a Break Condition is satisfied, emulation may stop after two or more instructions have
4. If a PC break address condition is set to the slot instruction after a delayed branch instruction,
5. Note on DSP repeat loop:
of the [Configuration] dialog box, a BREAKPOINT is set to a physical address. A
BREAKPOINT is set after disabling the SH7729 or SH7709A MMU upon program execution.
After setting, the MMU is returned to the original state. When a break occurs at the
corresponding virtual address, the cause of termination displayed in the status bar and the
[System Status] window is ILLEGAL INSTRUCTION, not BREAKPOINT.
the [Configuration] dialog box, a BREAKPOINT is set to a virtual address. A BREAKPOINT
is set after enabling the SH7729 or SH7709A MMU upon program execution. After setting,
the MMU is returned to the original state. When an ASID value is specified, the breakpoint is
set to the virtual address corresponding to the ASID value. The emulator sets the breakpoint
after rewriting the ASID value to the specified value, and returns the ASID value to its original
value after setting. When no ASID value is specified, the breakpoint is set to a virtual address
corresponding to the ASID value at command input.
is set. Accordingly, even if the VP_MAP table is modified after breakpoint setting, the
breakpoint address remains unchanged. When a breakpoint is satisfied with the modified
address in the VP_MAP table, the cause of termination displayed in the status bar and the
[System Status] window is ILLEGAL INSTRUCTION, not BREAKPOINT.
address is filled immediately before and after user program execution.
A breakpoint is equal to a branch instruction. In some DSP repeat loops, branch instructions
cannot be set. For these cases, do not set breakpoints. Refer to the hardware manual for
details.
executed. Accordingly, do not set a BREAKPOINT to an instruction which satisfies Break
Condition 2.
been executed.
user program execution cannot be terminated before the slot instruction execution; execution
stops before the branch destination instruction.
A breakpoint is equal to a branch instruction. In some DSP repeat loops, branch instructions
cannot be set. For these cases, do not set breakpoints. Refer to the hardware manual for
details.
Notes on Setting the [Break Condition] Dialog Box
Rev. 2.0, 01/01, page 205 of 216

Related parts for HD6417729