ADUM7440_11 AD [Analog Devices], ADUM7440_11 Datasheet - Page 7

no-image

ADUM7440_11

Manufacturer Part Number
ADUM7440_11
Description
1 kV RMS Quad-Channel Digital Isolators
Manufacturer
AD [Analog Devices]
Datasheet
PACKAGE CHARACTERISTICS
Table 13.
Parameter
Resistance (Input-to-Output)
Capacitance (Input-to-Output)
Input Capacitance
IC Junction-to-Ambient Thermal
1
2
REGULATORY INFORMATION
The ADuM744x is approved by the organizations listed in Table 14. See Table 18 and the Insulation Lifetime section for recommended
maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 14.
UL
Recognized under UL 1577 Component
Recognition Program
Single Protection,
1000 V rms Isolation Voltage
File E274400
1
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 15.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
The device is considered a 2-terminal device: Pin 1 through Pin 8 are shorted together and Pin 9 through Pin 16 are shorted together.
Input capacitance is from any input data pin to ground.
In accordance with UL 1577, each ADuM744x is proof tested by applying an insulation test voltage ≥1200 V rms for 1 sec (current leakage detection limit = 5 µA).
Figure 4. Thermal Derating Curve, Dependence of Safety-Limiting Values
Resistance
350
300
250
200
150
100
50
0
0
with Case Temperature per DIN V VDE V 0884-10
2
50
1
CASE TEMPERATURE (°C)
1
1
100
150
Symbol
R
C
C
θ
I-O
JA
I-O
I
Symbol
L(I01)
L(I02)
CTI
CSA (Pending)
Approved under CSA Component
Acceptance Notice #5A
Basic insulation per CSA 60950-1-03 and IEC 60950-1, 148 V rms (210 V peak)
maximum working voltage
File 205078
200
Min
Rev. B | Page 7 of 20
Typ
10
2
4.0
76
Value
1000
3.8
2.8
2.6
>175
IIIa
13
Max
Unit
V rms
mm min
mm min
μm min
V
RECOMMENDED OPERATING CONDITIONS
Table 16.
Parameter
Operating Temperature
Supply Voltages
Input Signal Rise and Fall Times
1
All voltages are relative to their respective ground. See the DC Correctness
and Magnetic Field Immunity section for information on immunity to external
magnetic fields.
Unit
pF
pF
°C/W
ADuM7440/ADuM7441/ADuM7442
Test Conditions
f = 1 MHz
Thermocouple located at center of package
underside
Conditions
1-minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
1
Symbol
T
V
A
DD1
, V
DD2
Min
−40
3.0
Max
+105
5.5
1.0
Unit
°C
V
ms