HIP0080 Intersil Corporation, HIP0080 Datasheet

no-image

HIP0080

Manufacturer Part Number
HIP0080
Description
Quad Inverting Power Drivers with Serial Diagnostic Interface
Manufacturer
Intersil Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HIP0080
Quantity:
44
Part Number:
HIP0080AM
Quantity:
5 510
Part Number:
HIP0080AM
Manufacturer:
SIEMENS
Quantity:
5 510
Quad Inverting Power Drivers with Serial
Diagnostic Interface
HIP0080, HIP0081The HIP0080/0081 Quad Power Drivers
contain four individually protected NDMOS power output
transistor switches to drive inductive and resistive loads
such as: relays, solenoids, injectors, AC and DC motors,
heaters and incandescent lamp displays. The 4 Power
Drivers are low-side switches driven by CMOS logic input
control stages. Each Output Power Driver is protected
against over-current, over-temperature and over-voltage.
An internal drain-to-gate zener diode provides the clamping
protection for over-voltage. Diagnostic circuits provide
ground short, supply short, open load and thermal overload
detection for each of the 4 output stages. Each of the 4
input drivers and their respective diagnostic filters are
controlled by one ENABLE input.
HIP0080, HIP0081The inputs are CMOS logic compatible
and individually control the output drivers with an active
high state for turn-on. All other control inputs are active
high with the exception of the Chip Select (CS) which is
active low. The DATAIN (DI) and DATAOUT (DO) are
positive logic and the Clock (CLK) input for the Serial
Interface is active on the rising edge of the CLK pulse. All
Inputs except the HIP0080 ENABLE have a nominal level
of hysteresis. IN1, IN2, IN3, IN4 and ENABLE have pull-
down resistors of approximately 100k . This switches off
any channel that has an unterminated input.
HIP0080, HIP0081Filters are used on the outputs of the
fault sensing comparators to avoid the detection of short
duration transient spikes. The on-chip oscillator is used to
clock an internal shift register in each filter. If the fault
condition is longer than a preset number of clock cycles,
the fault condition is recognized and the respective bit is
set in the diagnostic register. No filter is used in the
thermal-overload feedback circuit and the bit is set when
thermal shutdown occurs.
HIP0080, HIP0081For normal operating conditions, a
Reset turns off all outputs when the V
3.5V. The internal bandgap and bias supply function
includes a 5V regulated supply for the low voltage signal
and logic circuits.
1
CC
level drops below
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
http://www.intersil.com or 407-727-9207
Features
• Low Side Power MOSFET Output Drivers
• Output Driver Protection
• HIP0081 Output Current Switching Capability:
• HIP0080 Output Current Switching Capability:
• HIP0080 - Low Idle Current Shutdown Mode
• Regulated Interface for 5V CMOS Logic Inputs
• Open Drain High Z DATAOUT
• Fault Mode Output for Shorts, Opens and Over-Temperature
• 16-Bit Serial Diagnostic Register
• SPI Bus Compatible Data Readout
• HIP0081 - Low
• -40
Applications
• Drivers For:
Ordering Information
HIP0081AS1
HIP0081AS2
HIP0080AM
- Over-Current Shutdown
- Over-Temperature Shutdown with Hysteresis
- Over-Voltage Internal Clamp
- Each Output, I
- All Outputs ON, Equal I
- All Outputs ON, Equal I
- Each Output, I
- All Outputs ON, Unequal I
- All Outputs ON, Unequal I
- Solenoids
- Relays
- Power Output
- Lamps
PART NUMBER
o
C to 125
September 1998
o
C Operating Temperature Range
OUT
OUT
JC
RANGE (
- Injectors
- Steppers
- Motors
- Displays
Power Package . . . . . . . . . . . . 3
-40 to 125
-40 to 125
-40 to 125
TEMP.
. . . . . . . . . . . . . . . . . . . . . . 2.2A DC
. . . . . . . . . . . . . . . . . . . . . . 1.3A DC
HIP0080, HIP0081
OUT
OUT
|
o
OUT
OUT
Copyright
C)
. . . . . . . . . . . . . . . . 6A DC
. . . . . . . . . . 8A PK, 500ms
File Number 3018.4
15 Ld SIP
15 Ld SIP
28 Ld PLCC
. . . . . . . . . . . . . . 3A DC
. . . . . . . . 4A PK, 500ms
• System Use:
PACKAGE
©
- Automotive
- Appliances
- Industrial
- Robotics
Intersil Corporation 1999
Z15.05A
Z15.05B
N28.45
PKG.
NO.
o
C/W

Related parts for HIP0080

HIP0080 Summary of contents

Page 1

... IN1, IN2, IN3, IN4 and ENABLE have pull- down resistors of approximately 100k . This switches off any channel that has an unterminated input. HIP0080, HIP0081Filters are used on the outputs of the fault sensing comparators to avoid the detection of short duration transient spikes. The on-chip oscillator is used to clock an internal shift register in each filter ...

Page 2

... POTENTIAL AS PIN 8-GND Functional Block Diagram SWITCH/CHANNELS V 100k IN1 DR1-CNTL POR CS CONTROL AND 16-BIT CLK DATAOUT DO DATAIN ENABLE (NOTE) POWER DOWN SWITCH 100k NOTE: HIP0080 - No enable hysteresis. 2 HIP0080, HIP0081 O.L. FILTER 1 CC G.S. FILTER S.C. FILTER (PWR-ON-RST) EN FCLK DIAGNOSTIC SHIFT ...

Page 3

... OF 4 SWITCH/CHANNELS (SEE FUNCTIONAL BLOCK DIAGRAM) IN1 DR1 CNTL (DATAPATH) 4 IN2 DR2 CNTL (DATAPATH) 4 IN3 DR3 CNTL (DATAPATH) 4 IN4 DR4 CNTL (DATAPATH POR CONTROL OSC 3 (HIP0080 ONLY) OUT1 DR OUT1 (DRVR) 4 OUT2 DR OUT2 (DRVR) 4 OUT3 DR OUT3 (DRVR) 4 OUT4 DR OUT4 (DRVR BANDGAP AND BIAS DATAOUT ...

Page 4

... PC Board with 2 sq. in oz. surface mount ground copper extending away from the package. For additional Power Dissipation Derating information, see Figure 8 curves. 4. Refer to Figures 4 and 5 Single Pulse Output Clamp Energy vs. Time Capability of the HIP0080 and HIP0081. The safe margin for single pulse energy operation is below the dotted line shown in Figures 4 and 5. ...

Page 5

... CC LOAD V = 14V LOAD 125 - Enable Low (N.A. to HIP0080 ENABLE) IN1, IN2, IN3, IN4 and ENABLE V = 7V, DO OFF (High 1.6mA (Low 4.5V Note 5.5V to 16V 5.5V to 16V 5.5V to 16V CC HIP0080 HIP0081 ...

Page 6

... HIP0080, HIP0081The last IC in the string ORs its own 16 fault bits in the parallel diagnostic register data and sends this data bit to an Error Flag register. The Error Flag register outputs the presence of a fault in one or more bits of the parallel diagnostic data register ...

Page 7

... FAULT determine the Single Pulse Energy capability. The energy SYMBOL in Joules is calculated from the following equation: OT1 HIP0080, HIP0081Single Pulse Energy = VDS tON . SB1 SG1 HIP0080, HIP0081Refer to Application Note 9416 for further information on Single Pulse Energy ratings for OI1 ...

Page 8

... DIAG. DATA REG. LOGIC CLK START OF 16 DIAGNOSTIC DATA BITS GATE OT1 SB1 SG1 OI1 ERROR FLAG BIT FIGURE 2. DATA AND CLOCK TIMING 8 HIP0080, HIP0081 16-BIT SERIAL ERROR FLAG BIT DIAG. DATA REG GATE S U5 FIGURE 1 ...

Page 9

... HIP0080, HIP0081Since this solution relates only to the package, further consideration must be given to a practical heat sink. The equation of linear heat flow assumes that the thermal resistance from Junction-to-Ambient ( the sum of the thermal resistance from Junction-to-Case and the thermal resistance from Case (heat sink)-to- Ambient ...

Page 10

... C. For a given application, Equation 1 determines the dissipation, P HIP0080, HIP0081Assume the package is mounted to a heat sink having a thermal resistance of 6 given application, assume the dissipation is 3W and the o ambient temperature ( 100 C ...

Page 11

... CURVE (4): r THERMAL RESISTANCE, 0 CASE (HEAT SINK TAB) TEMPERATURE ( FIGURE 7. HIP0081 CURRENT vs CASE (TAB) TEMPERATURE, ALL OUTPUTS ON WITH EQUAL CURRENT HIP0080 WITH (PC BOARDS AS HEAT SINK -50 -25 0 AMBIENT TEMPERATURE ( FIGURE 8. DISSIPATION DERATING CURVES 11 HIP0080, HIP0081 MAX ...

Page 12

... E1 include mold mismatch and are measured at the extreme material condition at the body parting line. - measured at seating plane 5. Centerline to be determined where center leads exit plastic body. 6. “N” is the number of terminal positions. 12 HIP0080, HIP0081 N28.45 0.004 (0.10 LEAD PLASTIC LEADED CHIP CARRIER PACKAGE 0.025 (0.64) R ...

Page 13

... E2 TAB DETAIL NOTES: 1. Refer to series symbol list, JEDEC Publication No. 95. 2. Dimensioning and Tolerancing per ANSI Y14.5M-1982 the number of terminals. 4. Controlling dimension: INCH. 13 HIP0080, HIP0081 Z15.05A A SEE TAB 15 LEAD PLASTIC SINGLE-IN-LINE PACKAGE STAGGERED F DETAIL VERTICAL LEAD FORM SYMBOL ...

Page 14

... LEAD TIPS 0.814 0.407 OF 0.150 C L 0.030 TYP 0.050 TYP 0.350 0.700 14 HIP0080, HIP0081 -Z- Z15.05B A 15 LEAD PLASTIC SINGLE-IN-LINE PACKAGE SURFACE F MOUNT “GULLWING” LEAD FORM E2 SYMBOL - ...

Page 15

... For information regarding Intersil Corporation and its products, see web site http://www.intersil.com Sales Office Headquarters NORTH AMERICA Intersil Corporation P. O. Box 883, Mail Stop 53-204 Melbourne, FL 32902 TEL: (407) 724-7000 FAX: (407) 724-7240 15 HIP0080, HIP0081 EUROPE Intersil SA Mercure Center 100, Rue de la Fusee 1130 Brussels, Belgium TEL: (32) 2.724.2111 FAX: (32) 2.724.22.05 ASIA Intersil (Taiwan) Ltd ...