0809-0010 EnerSys, 0809-0010 Datasheet - Page 6

BATT CYCLON SLA 4V 5.0AH

0809-0010

Manufacturer Part Number
0809-0010
Description
BATT CYCLON SLA 4V 5.0AH
Manufacturer
EnerSys
Series
Cyclon®r
Type
Sealed Lead Acid Batteriesr
Datasheets

Specifications of 0809-0010

Voltage - Rated
4V
Capacity
5.0Ah
Size / Dimension
3.80" Dia x 2.12" H (96.5mm x 53.8mm)
Termination Style
Spade, .250" (6.3mm)
Rechargeability
Yes
Weight
0.1 lb (45.36g)
Output Voltage
4 V
Chemistry
Lead Acid
Rechargeable/non-rechargeable
Rechargeable
Battery Capacity
5 Ah
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
842-1007
6
The pure lead advantage
8. Fastest recharge - EnerSys pure lead chemistry
9. Orientation/placement/transport - Due to the products'
www.enersys.com
Each plastic Monobloc consists of Single Cell elements,
internally connected to provide a 4 or 6 volt unit.
Monoblocs or Single Cells can be connected in series
or parallel to achieve the required voltage or capacity.
Monoblocs and Single Cells are supplied with spade
terminals making electrical connections quick and easy.
Additionally, EnerSys
pressure in the market. As a result, our batteries are
more resistant to venting and dryout from continuous
overcharge in standby applications.
allows our batteries and cells to offer the highest
recharge efficiency of any sealed-lead battery on the
market. With pure lead, you can achieve a 95%
state of recharge in less than one hour - without loss
of capacity or electrolyte using conventional
constant-voltage charging techniques.
Flexible charging options are possible with CYCLON
battery Single Cells and Monoblocs, as no current limit is
required when using a constant voltage charger.
mechanical design, CYCLON batteries can be mounted
and operated in any position, an attractive feature for less
accessible areas.
CYCLON battery Single Cells offer UL 94V-0 flame-
retardant packaging, thus allowing the mounting of
systems in sensitive areas and human environments.
Plus, the unique and flexible 2-volt CYCLON battery
Single Cell allows you to design your system using
an almost infinite number of packaging/design
configurations.
®
products offer the highest vent
®
10. Shelf life - Pure lead batteries have an extremely low
Effective September 30, 1995, CYCLON battery Single
Cells and Monoblocs were classified as “nonspillable
batteries”, and are excepted from the Department of
Transportation's comprehensive packaging requirements
if the following conditions are satisfied: (1) The battery
is protected against short circuits and is securely
packaged and (2) The battery and outer packaging
must be plainly and durably marked “NONSPILLABLE”
or “NONSPILLABLE BATTERY”. CYCLON battery
shipments from the EnerSys plant in Warrensburg,
Missouri will be properly labeled in accordance with
applicable regulations. Packaging changes performed
at other locations may require additional labeling, since
in addition to the battery itself containing the required
marking, the outer packaging of the battery must also
contain the required marking: “NONSPILLABLE” or
“NONSPILLABLE BATTERY”.
CYCLON battery Single Cells and Monoblocs have been
tested and determined to be in compliance with the
vibration and pressure differential tests contained in 49
CFR
Because CYCLON battery Single Cells and Monoblocs
are classified as “Nonspillable” and meet the conditions
above, [from
UN number nor do they require additional DOT hazard
labeling.
The regulation change effective September 1995, was
to clarify and distinguish to shippers and transporters,
all batteries that have been tested and determined to
be in compliance with the DOT Hazardous Material
Regulations, the International Civil Aeronautics
Organization (ICAO), and the International Air Transport
Association (IATA) Packaging Instruction 806 and Special
Provision A67, and therefore excepted from all other
requirements of these regulations and classified as a
“nonspillable battery”.
self-discharge rate, thus providing extended storage
capability while maintaining high state-of-charge levels
for dependable operation.
CYCLON battery Single Cells and Monoblocs have
a shelf life more than two times that of conventional
lead batteries. To assure maximum reliability, EnerSys
recommends that all stored cells/batteries be recharged
(boost charged) once every 24 months or when the open
circuit voltage drops to 2.00 volts per cell, whichever
occurs earlier. Inventory should be checked more
frequently if storage temperature regularly exceeds 25°C.
§
173.159(d).
§
173.159(d)] they do not have an assigned
Publication No: US-CYC-SG-003 - June 2008