Z8F041APH020SG2156 ZiLOG, Z8F041APH020SG2156 Datasheet - Page 50

no-image

Z8F041APH020SG2156

Manufacturer Part Number
Z8F041APH020SG2156
Description
8-bit Microcontrollers - MCU 4K FLASH 1K RAM 128B NVDS
Manufacturer
ZiLOG
Datasheet

Specifications of Z8F041APH020SG2156

Rohs
yes
Core
eZ8
Processor Series
Z8F041xx
Data Bus Width
8 bit
Maximum Clock Frequency
20 MHz
Program Memory Size
4 KB
Data Ram Size
1 KB
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 3.6 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
PDIP-20
Mounting Style
Through Hole
A/d Bit Size
10 bit
A/d Channels Available
8
Interface Type
UART
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
17
Number Of Timers
2
Program Memory Type
Flash
Supply Voltage - Max
3.6 V
Supply Voltage - Min
2.7 V
PS022827-1212
HALT Mode
Peripheral-Level Power Control
Power Control Register Definitions
Executing the eZ8 CPU’s HALT instruction places the device into HALT Mode, which
powers down the CPU but leaves all other peripherals active. In HALT Mode, the operat-
ing characteristics are:
The eZ8 CPU can be brought out of HALT Mode by any of the following operations:
To minimize current in HALT Mode, all GPIO pins that are configured as inputs must be
driven to one of the supply rails (V
In addition to the STOP and HALT modes, it is possible to disable each peripheral on each
of the Z8 Encore! XP F082A Series devices. Disabling a given peripheral minimizes its
power consumption.
The following sections define the Power Control registers.
Power Control Register 0
Each bit of the following registers disables a peripheral block, either by gating its system
clock input or by removing power from the block. The default state of the low-power
Primary oscillator is enabled and continues to operate
System clock is enabled and continues to operate
eZ8 CPU is stopped
Program counter (PC) stops incrementing
Watchdog Timer’s internal RC oscillator continues to operate
If enabled, the Watchdog Timer continues to operate
All other on-chip peripherals continue to operate, if enabled
Interrupt
Watchdog Timer time-out (interrupt or reset)
Power-On Reset
Voltage Brown-Out reset
External RESET pin assertion
P R E L I M I N A R Y
CC
or GND).
Z8 Encore! XP
Product Specification
®
F082A Series
HALT Mode
33

Related parts for Z8F041APH020SG2156