IS42S16400F-6TL ISSI, Integrated Silicon Solution Inc, IS42S16400F-6TL Datasheet - Page 5

IC SDRAM 64MBIT 166MHZ 54TSOP

IS42S16400F-6TL

Manufacturer Part Number
IS42S16400F-6TL
Description
IC SDRAM 64MBIT 166MHZ 54TSOP
Manufacturer
ISSI, Integrated Silicon Solution Inc
Type
SDRAMr
Datasheets

Specifications of IS42S16400F-6TL

Format - Memory
RAM
Memory Type
SDRAM
Memory Size
64M (4M x 16)
Speed
166MHz
Interface
Parallel
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
0°C ~ 70°C
Package / Case
54-TSOP II
Organization
4Mx16
Density
64Mb
Address Bus
14b
Access Time (max)
6/5.4ns
Maximum Clock Rate
166MHz
Operating Supply Voltage (typ)
3.3V
Package Type
TSOP-II
Operating Temp Range
0C to 70C
Operating Supply Voltage (max)
3.6V
Operating Supply Voltage (min)
3V
Supply Current
130mA
Pin Count
54
Mounting
Surface Mount
Operating Temperature Classification
Commercial
Data Bus Width
16 bit
Maximum Clock Frequency
166 MHz
Access Time
6 ns, 5.4 ns
Supply Voltage (max)
3.6 V
Supply Voltage (min)
3 V
Maximum Operating Current
130 mA
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
706-1075
IS42S16400F-6TL

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IS42S16400F-6TL
Manufacturer:
ISSI
Quantity:
20 000
Part Number:
IS42S16400F-6TLI
Manufacturer:
ISSI
Quantity:
5 530
Part Number:
IS42S16400F-6TLI
Manufacturer:
ISSI
Quantity:
6 250
Part Number:
IS42S16400F-6TLI
Manufacturer:
ISSI
Quantity:
1 831
IS42S16400F
IC42S16400F
AUTO PRECHARGE does not apply except in full-page
burst mode. Upon completion of the READ or WRITE
burst, a precharge of the bank/row that is addressed is
automatically performed.
AUTO REFRESH COMMAND
This command executes the AUTO REFRESH operation.
The row address and bank to be refreshed are automatically
generatedduringthisoperation. Thestipulatedperiod(t
required for a single refresh operation, and no other com-
mands can be executed during this period. This command is
executed at least 4096 times every 64ms. During an AUTO
REFRESH command, address bits are “Don’t Care”. This
command corresponds to CBR Auto-refresh.
SELF REFRESH
During the SELF REFRESH operation, the row address to
be refreshed, the bank, and the refresh interval are gen-
erated automatically internally. SELF REFRESH can be
used to retain data in the SDRAM without external clocking,
even if the rest of the system is powered down. The SELF
REFRESH operation is started by dropping the CKE pin
from HIGH to LOW. During the SELF REFRESH operation
all other inputs to the SDRAM become “Don’t Care”. The
device must remain in self refresh mode for a minimum
period equal to t
for an indefinite period beyond that.The SELF-REFRESH
operation continues as long as the CKE pin remains LOW
and there is no need for external control of any other pins.
The next command cannot be executed until the device
internal recovery period (t
goes HIGH, the NOP command must be issued (minimum
of two clocks) to provide time for the completion of any
internal refresh in progress. After the self-refresh, since it
is impossible to determine the address of the last row to
be refreshed, an AUTO-REFRESH should immediately be
performed for all addresses.
Integrated Silicon Solution, Inc. — www.issi.com
Rev. A
03/19/08
ras
or may remain in self refresh mode
rc
) has elapsed. Once CKE
rc
) is
BURST TERMINATE
The BURST TERMINATE command forcibly terminates
the burst read and write operations by truncating either
fixed-length or full-page bursts and the most recently
registered READ or WRITE command prior to the BURST
TERMINATE.
COMMAND INHIBIT
COMMAND INHIBIT prevents new commands from being
executed. Operations in progress are not affected, apart
from whether the CLK signal is enabled
NO OPERATION
When CS is low, the NOP command prevents unwanted
commands from being registered during idle or wait
states.
LOAD MODE REGISTER
During the LOAD MODE REGISTER command the mode
register is loaded from A0-A11. This command can only
be issued when all banks are idle.
ACTIVE COMMAND
When the ACTIVE COMMAND is activated, BA0, BA1
inputs selects a bank to be accessed, and the address
inputs on A0-A11 selects the row. Until a PRECHARGE
command is issued to the bank, the row remains open
for accesses.
5

Related parts for IS42S16400F-6TL