C8051F313R Silicon Labs, C8051F313R Datasheet - Page 60

no-image

C8051F313R

Manufacturer Part Number
C8051F313R
Description
8-bit Microcontrollers - MCU 8KB 10ADC
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F313R

Product Category
8-bit Microcontrollers - MCU
Core
8051
Data Bus Width
8 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
8 KB
Data Ram Size
1.25 KB
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 3.6 V
Package / Case
QFN-28
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
17
Data Rom Size
128 B
Interface Type
I2C, SMBus, SPI, UART
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
25
Number Of Timers
5
On-chip Dac
No
Processor Series
C8051
Program Memory Type
Flash
Factory Pack Quantity
1500
Supply Voltage - Max
3.6 V
Supply Voltage - Min
2.7 V
C8051F310/1/2/3/4/5/6/7
60
Bit7:
Bit6:
Bit5:
Bit4:
Bit3:
Bits2 – 0: AD0CM2 – 0: ADC0 Start of Conversion Mode Select.
AD0EN
R/W
Bit7
AD0EN: ADC0 Enable Bit.
0: ADC0 Disabled. ADC0 is in low-power shutdown.
1: ADC0 Enabled. ADC0 is active and ready for data conversions.
AD0TM: ADC0 Track Mode Bit.
0: Normal Track Mode: When ADC0 is enabled, tracking is continuous unless a conversion is
in progress.
1: Low-power Track Mode: Tracking Defined by AD0CM2-0 bits (see below).
AD0INT: ADC0 Conversion Complete Interrupt Flag.
0: ADC0 has not completed a data conversion since the last time AD0INT was cleared.
1: ADC0 has completed a data conversion.
AD0BUSY: ADC0 Busy Bit.
Read:
0: ADC0 conversion is complete or a conversion is not currently in progress. AD0INT is set to
logic 1 on the falling edge of AD0BUSY.
1: ADC0 conversion is in progress.
Write:
0: No Effect.
1: Initiates ADC0 Conversion if AD0CM2-0 = 000b
AD0WINT: ADC0 Window Compare Interrupt Flag.
0: ADC0 Window Comparison Data match has not occurred since this flag was last cleared.
1: ADC0 Window Comparison Data match has occurred.
When AD0TM = 0:
000: ADC0 conversion initiated on every write of ‘1’ to AD0BUSY.
001: ADC0 conversion initiated on overflow of Timer 0.
010: ADC0 conversion initiated on overflow of Timer 2.
011: ADC0 conversion initiated on overflow of Timer 1.
100: ADC0 conversion initiated on rising edge of external CNVSTR.
101: ADC0 conversion initiated on overflow of Timer 3.
11x: Reserved.
When AD0TM = 1:
000: Tracking initiated on write of ‘1’ to AD0BUSY and lasts 3 SAR clocks, followed by con-
version.
001: Tracking initiated on overflow of Timer 0 and lasts 3 SAR clocks, followed by conversion.
010: Tracking initiated on overflow of Timer 2 and lasts 3 SAR clocks, followed by conversion.
011: Tracking initiated on overflow of Timer 1 and lasts 3 SAR clocks, followed by conversion.
100: ADC0 tracks only when CNVSTR input is logic low; conversion starts on rising CNVSTR
edge.
101: Tracking initiated on overflow of Timer 3 and lasts 3 SAR clocks, followed by conversion.
11x: Reserved .
AD0TM
R/W
Bit6
SFR Definition 5.6. ADC0CN: ADC0 Control
AD0INT AD0BUSY AD0WINT AD0CM2 AD0CM1 AD0CM0 00000000
R/W
Bit5
R/W
Bit4
Rev. 1.7
R/W
Bit3
R/W
Bit2
R/W
Bit1
(bit addressable)
R/W
Bit0
SFR Address:
Reset Value
0xE8

Related parts for C8051F313R